Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

CAGE Information

Code Company
80008 ELECTRO ENGINEERING WORKS INC

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
ACZD TRANSFORMER WINDING CONNECTION TYPE DELTA-DELTA AND WYE-WYE
AKNA INCLOSURE TYPE FULLY INCLOSED
ACZX WINDING SHIELDING METHOD INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT
FEAT SPECIAL FEATURES LINKS PROVIDED FOR ADJUSTING PRIMARY VOLTAGE AND CHANGING FROM DELTA TO WYE WITHOUT DISTRUBING SUPPLY CONDUCTORS,PRIMARY VOLTAGE 346 THRU 433 AND SECONDARY VOLTAGE 5200 ARE WYE CONNECTED
CWJS WINDING OPERATING VOLTAGE 550.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
ACZC INPUT-OUTPUT PHASE RELATIONSHIP THREE PHASE TO THREE PHASE SINGLE COMPONENT
AARG RELIABILITY INDICATOR NOT ESTABLISHED
CRMJ WINDING POWER RATING 53.5 K1LOVOLT-AMPERES SINGLE COMPONENT ALL SECONDARY
ACZB FREQUENCY RATING 50.0 HERTZ NOMINAL SINGLE COMPONENT AND 60.0 HERTZ NOMINAL SINGLE COMPONENT
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT
CWJS WINDING OPERATING VOLTAGE 5.20 AC MINOR WET SINGLE COMPONENT 2ND SECONDARY
TTQY TERMINAL TYPE AND QUANTITY 14 THREADED STUD
ADAQ BODY LENGTH 33.375 INCHES NOMINAL
ADAT BODY WIDTH 32.750 INCHES NOMINAL
ADAU BODY HEIGHT 18.375 INCHES NOMINAL
CWJS WINDING OPERATING VOLTAGE 220.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 240.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 346.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 364.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 200.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 398.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 250.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 230.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 210.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 415.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 381.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 433.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
CQLC WINDING TAP LOCATION (NON-CORE) MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY

Similar Parts

E13858 , E13858 , 5950-00-583-4447 , 5950005834447 , 005834447