RELAY , ELECTROMAGNETIC

Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

CAGE Information

Code Company
23598 ROSS ENGINEERING CORPORATION

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKDX WINDING QUANTITY 1
ABKW OVERALL HEIGHT 7.670 INCHES NOMINAL
ABMK OVERALL WIDTH 2.840 INCHES NOMINAL
ADZC ENVIRONMENTAL PROTECTION DUSTPROOF
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 25000.0 DC
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 2.875 INCHES NOMINAL SINGLE MOUNTING FACILITY
AJSS FREQUENCY IN HERTZ 60.0 NOMINAL
APCN COIL QUANTITY 1
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.125 INCHES NOMINAL SINGLE MOUNTING FACILITY
AXHR MOUNTING FACILITY TYPE AND QUANTITY 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY
ABHP OVERALL LENGTH 3.380 INCHES NOMINAL
APNP DUTY TYPE CONTINUOUS
CRNG NONPILE-UP MAIN CONTACT ARRANGEMENT 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.203 INCHES NOMINAL SINGLE MOUNTING FACILITY
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 115.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING
CSKP NONPILE-UP AUXILIARY CONTACT ARRANGEMENT 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 125.0 AMPERES DC RESISTIVE LOAD
TTQY TERMINAL TYPE AND QUANTITY 8 SCREW ALL FUNCTIONS
CQYJ MOUNTING FACILITY PATTERN RECTANGULAR SINGLE MOUNTING FACILITY