Part Number
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
CAGE Information
Code | Company |
---|---|
73631 | POWERS HOLDINGS INC DBA CURTIS INDUS |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
SFTT | SURFACE TREATMENT | CADMIUM TERMINALS |
SFTT | SURFACE TREATMENT | CADMIUM TERMINALS |
ABCS | TERMINAL ROW QUANTITY | 1 |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.125 INCHES |
ABGS | BASE THICKNESS | 0.281 INCHES |
ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 0.562 INCHES |
CQCW | FEEDTHRU CONNECTION END TYPE | 857 FOURTH COMBINATION BOTH ENDS |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | MIL-M-14,TYPE CFG MIL SPEC SINGLE MATERIAL RESPONSE BOARD |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.219 INCHES |
CQCW | FEEDTHRU CONNECTION END TYPE | 433 15TH MATERIAL RESPONSE BOTH ENDS |
CRZR | FEEDTHRU TERMINAL QUANTITY | 10 SINGLE COMBINATION |
AAMA | MOUNTING HOLE DIAMETER | 0.141 INCHES |
ABGN | BOARD OVERALL LENGTH | 4.375 INCHES |
ABGQ | BOARD OVERALL HEIGHT | 0.812 INCHES |
CWLG | TERMINAL PATTERN ARRANGEMENT | SINGLE ROW |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.375 INCHES |
CWLN | TERMINAL DESIGN | VERTICAL FEEDTHRU |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.125 INCHES |
ABCX | BOARD CONSTRUCTION | HOLLOW CONSTRUCTION WITHOUT INSULATED STRIP |
ABGP | BOARD OVERALL WIDTH | 0.688 INCHES |
MATT | MATERIAL | PLASTIC PHENOLIC BOARD AND CELLULOSE BOARD |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE |
AAQL | BODY STYLE | BARRIER TYPE |