Part Number
Part Number:
NSN:
NIIN:
Item Name:
SWITCH , THERMOSTATIC
Definition:
A SWITCH THAT IS ACTUATED BY CHANGES IN AMBIENT TEMPERATURE. EXCLUDES CIRCUIT BREAKER; CONTROL, TEMPERATURE (AS MODIFIED); FUSE (AS MODIFIED); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; AND THERMOSTAT, FLOW CONTROL. SEE ALSO CONTROL, TEMPERATURE (AS MODIFIED) AND REGULATOR, TEMPERATURE (AS MODIFIED).
CAGE Information
Code | Company |
---|---|
04814 | CHATHAM CONTROLS CORP |
Federal Supply Class
Title
SWITCHES
Inclusions:
INCLUDES ROTARY, KNIFE, TOGGLE, PUSH BUTTON, MERCURY, THERMOSTATIC, AND DIFFERENTIAL PRESSURE SWITCHES.
Exclusions:
EXCLUDES SWITCHGEAR.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
AWTN | OPERATING TEMP RATING | 150.0 DEG CELSIUS MAXIMUM AND -20.0 DEG CELSIUS MINIMUM |
CSCF | TERMINAL TYPE | TAB, SOLDER LUG |
ABHP | OVERALL LENGTH | 0.688 INCHES MAXIMUM |
CTHF | CONTACT LOAD CURRENT RATING | 750.0 MILLIAMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE, PRESET |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL SECOND VOLTAGE |
AGAV | END ITEM IDENTIFICATION | GENERAL PURPOSE ELECTRONIC TEST EQUIPMENT (GPETE). |
ABPM | BODY DIAMETER | 0.250 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.460 INCHES MAXIMUM |
AXGY | MOUNTING METHOD | CLAMP |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | VAPORTIGHT, GASTIGHT |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
FREQ | FREQUENCY IN HERTZ | 60.0 SINGLE VOLTAGE |
AKBY | TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
ADAV | OVERALL DIAMETER | 0.250 INCHES NOMINAL |
STYL | STYLE DESIGNATOR | CYLINDRICAL |
CTYM | CONTACT ADJUSTMENT RANGE | +20.00/+90.00 ACTUATION POINT DEGREES CELSIUS |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
CTYX | CONTACT STIMULUS RATING | 55.00 ACTUATION POINT NOMINAL DEGREES CELSIUS AND 54.50 DEACTUATION POINT NOMINAL DEGREES CELSIUS |
CTHF | CONTACT LOAD CURRENT RATING | 750.0 MILLIAMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT SCREW |