Part Number
Part Number:
NSN:
NIIN:
Item Name:
FAN , VANEAXIAL
Definition:
A NONPOSITIVE DISPLACEMENT MECHANICAL DEVICE WITH GUIDE VANES AND HAVING AN AXIAL FAN IMPELLER(S) INCLOSED WITHIN A TUBULAR HOUSING. IT IS DESIGNED PRIMARILY FOR DUCT INSTALLATION TO MOVE AIR OR GAS AXIALLY OVER A WIDE RANGE OF VOLUMES AND PRESSURES.
CAGE Information
Code | Company |
---|---|
66137 | WING INDUSTRIES |
Federal Supply Class
Title
FANS, AIR CIRCULATORS, AND BLOWE
Inclusions:
INCLUDES WALL TYPE FANS; PEDESTAL TYPE FANS; HOUSEHOLD TYPE AND ATTIC TYPE EXHAUST FANS; FLOOR FANS; FORGED DRAFT EXHAUST AND DISPOSAL KITS; FANS, AIR CIRCULATORS, AND BLOWER EQUIPMENT, WHETHER DESIGNATED AS "INDUSTRIAL" OR "NONINDUSTRIAL" BY APPLICATION AND/OR USE.
Exclusions:
EXCLUDES COMBINATION HEATER-FANS (FSC 4520).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ZZZT | NONDEFINITIVE SPEC/STD DATA | A TYPE |
CQKX | AIR FLOW RATE | 1000.0 CUBIC FEET PER MINUTE NOMINAL |
ABMZ | DIAMETER | 12.715 INCHES NOMINAL |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 65.0 DEG CELSIUS |
STYL | STYLE DESIGNATOR | FIXED |
MATT | MATERIAL | STEEL HOUSING |
AKCV | DRIVE TYPE | DIRECT |
NMBR | QUANTITY | 1 |
AKDJ | PRIME MOVER TYPE | ELECTRIC MOTOR |
CWLY | PRIME MOVER DRIVE SHAFT BEARING TYPE | BALL |
AJLY | STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | 2.5 INCHES OF WATER |
CSYL | PRIME MOVER POWER RATING | 1.000 HORSEPOWER |
AAYD | STAGE QUANTITY | 1 |
ZZZY | REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | ASDIFFERENTIATED BY PRIME MOVER REQUIREMENTS |
AYSY | ROTATION DIRECTION FOR WHICH DESIGNED | CLOCKWISE |
CSBH | VOLTAGE IN VOLTS AND CURRENT TYPE | 230.0 DC |
MATT | MATERIAL | ALUMINUM BLADE |
AKNA | INCLOSURE TYPE | PARTIALLY INCLOSED |
CWLX | HOUSING INSIDE DIAMETER | 12.688 INCHES NOMINAL |
AEQC | OPERATING SPEED AT RATED CAPACITY IN RPM | 3450.0 |