Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

CAGE Information

Code Company
08779 SIGNAL TRANSFORMER CO INC

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CRBZ WINDING OPERATING CURRENT 240.0 MILLIAMPERES NOMINAL B SINGLE COMPONENT ALL SECONDARY
TTQY TERMINAL TYPE AND QUANTITY 6 TAB, SOLDER LUG
ABHP OVERALL LENGTH 1.375 INCHES NOMINAL
PKWT UNPACKAGED UNIT WEIGHT (NON-CORE) 3.000 OUNCES
AARG RELIABILITY INDICATOR NOT ESTABLISHED
ACZF MAXIMUM TRANSFORMER POWER RATING 1.2 VOLT-AMPERE SINGLE COMPONENT
ABKW OVERALL HEIGHT 1.376 INCHES NOMINAL
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT
CBME CUBIC MEASURE (NON-CORE) 2.13 CUBIC INCHES
ABMK OVERALL WIDTH 1.125 INCHES NOMINAL
CWJS WINDING OPERATING VOLTAGE 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
ACZB FREQUENCY RATING 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 500.0 HERTZ MAXIMUM SINGLE COMPONENT
CWJS WINDING OPERATING VOLTAGE 5.00 AC POUNDS PER HOUR WET SINGLE COMPONENT ALL SECONDARY
AKNA INCLOSURE TYPE OPEN
AXGY MOUNTING METHOD TERMINAL SINGLE GROUP

Similar Parts

EP10-120 , EP10120 , 5950-01-006-0147 , 5950010060147 , 010060147