Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
CAGE Information
Code | Company |
---|---|
71279 | INTERCONNECTION PRODUCTS INC |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABCX | BOARD CONSTRUCTION | SOLID CONSTRUCTION |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | MIL-P-18177,TYPE GEE MIL SPEC SINGLE MATERIAL RESPONSE BOARD |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.312 INCHES |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.060 INCHES |
ABGP | BOARD OVERALL WIDTH | 1.610 INCHES |
ABCS | TERMINAL ROW QUANTITY | 2 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 UNTHREADED HOLE |
CWLG | TERMINAL PATTERN ARRANGEMENT | MULTI-ROW |
CRNL | NONFEEDTHRU TERMINAL TYPE | 434 SINGLE |
CSCS | NONFEEDTHRU TERMINAL QUANTITY | 12 SINGLE |
ABGT | BOARD THICKNESS | 0.093 INCHES |
AAQL | BODY STYLE | STRIP TYPE |
CWLN | TERMINAL DESIGN | NONFEEDTHRU |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.180 INCHES |
AAPB | DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 1500.0 |
MATT | MATERIAL | COPPER ALLOY 360 TERMINALS |
ABGN | BOARD OVERALL LENGTH | 2.420 INCHES |
MATT | MATERIAL | PLASTIC EPOXY BOARD AND CELLULOSE BOARD |
AAMA | MOUNTING HOLE DIAMETER | 0.127 INCHES |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | QQ-B-626,COMP 22 1/2 H FED SPEC SINGLE MATERIAL RESPONSE TERMINALS |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.180 INCHES |
ABDV | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.625 INCHES |
ABCU | DISTANCE BETWEEN TERMINAL ROW CENTERS | 1.250 INCHES |