Part Number
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
CAGE Information
Code | Company |
---|---|
64959 | AMERICAN TELEPHONE AND TELEGRAPH CO |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 0.750 INCHES |
ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 0.750 INCHES |
MATT | MATERIAL | PLASTIC BOARD |
CQCW | FEEDTHRU CONNECTION END TYPE | 858 FOURTH COMBINATION BOTH ENDS |
ABCS | TERMINAL ROW QUANTITY | 1 |
CRZR | FEEDTHRU TERMINAL QUANTITY | 3 SINGLE COMBINATION |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.156 INCHES |
ABGN | BOARD OVERALL LENGTH | 2.312 INCHES |
CQCW | FEEDTHRU CONNECTION END TYPE | 433 15TH MATERIAL RESPONSE BOTH ENDS |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.500 INCHES |
ABGS | BASE THICKNESS | 0.375 INCHES |
CWLG | TERMINAL PATTERN ARRANGEMENT | SINGLE ROW |
MATT | MATERIAL | COPPER ALLOY TERMINALS |
CWLN | TERMINAL DESIGN | VERTICAL FEEDTHRU |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.250 INCHES |
AAMA | MOUNTING HOLE DIAMETER | 0.152 INCHES |
ABCX | BOARD CONSTRUCTION | HOLLOW CONSTRUCTION WITHOUT INSULATED STRIP |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.000 INCHES |
ABGQ | BOARD OVERALL HEIGHT | 1.094 INCHES |
ABGP | BOARD OVERALL WIDTH | 0.500 INCHES |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE |
AAQL | BODY STYLE | BARRIER TYPE |