Part Number
Part Number:
NSN:
NIIN:
Item Name:
RELAY , THERMAL
Definition:
A RELAY SWITCH WHICH IS ACTUATED BY THE EFFECT OF INTERNAL HEAT GENERATED BY THE CURRENT IN ITS ENERGIZING CIRCUIT. FOR ITEMS ACTUATED BY AMBIENT, RATHER THAN INTERNAL TEMPERATURE CHANGES, SEE SWITCH, THERMOSTATIC.
CAGE Information
Code | Company |
---|---|
93929 | SPX CORPORATION DBA RADIODETECTION |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CYCS | CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
ABHP | OVERALL LENGTH | 1.750 INCHES NOMINAL |
TTQY | TERMINAL TYPE AND QUANTITY | 4 QUICK DISCONNECT, MALE |
CYCT | CONTACT MAXIMUM CURRENT RATING IN AMPS | 2.0 AC OR 1.0 DC |
CYCW | DELAY TIME IN SECONDS | 120.0 FIXED OPERATE NOMINAL |
ABMK | OVERALL WIDTH | 1.375 INCHES NOMINAL |
FEAT | SPECIAL FEATURES | TWO HOLES FOR NO. 4 SCREWS SPACED 1.125 IN. C TO C |
APFR | CONTACT ARRANGEMENT | SINGLE POLE, SINGLE THROW, NORMALLY OPEN |
CYCU | HEATER VOLTAGE RATING IN VOLTS | 115.0 |
ABKW | OVERALL HEIGHT | 1.156 INCHES NOMINAL |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE |