Part Number
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
72149 | ELECTRONIC TRANSFORMER CORP. |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
TTQY | TERMINAL TYPE AND QUANTITY | 7 WIRE LEAD |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 72.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 6.30 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 151.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ACZB | FREQUENCY RATING | 320.0 HERTZ MINIMUM SINGLE COMPONENT AND 480.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | EXTERNAL INCLOSURE SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 15.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT SINGLE SECONDARY |
ADAU | BODY HEIGHT | 0.875 INCHES MAXIMUM |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
ADAQ | BODY LENGTH | 0.968 INCHES MINIMUM AND 1.031 INCHES MAXIMUM |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | OPEN |
AXGY | MOUNTING METHOD | TERMINAL SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 35.0 MILLIAMPERES NOMINAL B SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 20.50 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY |
CQLC | WINDING TAP LOCATION (NON-CORE) | MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |
ADAT | BODY WIDTH | 0.703 INCHES MINIMUM AND 0.766 INCHES MAXIMUM |