Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
CIRCUIT BREAKER

Definition:

A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.

CAGE Information

Code Company
30086 SPD ELECTRICAL SYSTEMS INC

Federal Supply Class

Title

CIRCUIT BREAKERS

Inclusions:

INCLUDES CIRCUIT BREAKERS AND CUTOUTS.

Exclusions:

EXCLUDES RELAYS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
ADAT BODY WIDTH 3.343 INCHES NOMINAL
FREQ FREQUENCY IN HERTZ 60.0 ALL LOCATIONS
AKPX POLE QUANTITY 3
AEHA DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 2.937 INCHES NOMINAL
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 2.625 INCHES NOMINAL
CXCY PART NAME ASSIGNED BY CONTROLLING AGENCY CIRCUIT BREAKER
CQJX NOMINAL THREAD SIZE 0.216 INCHES
AGAV END ITEM IDENTIFICATION VIRGINA CLASS SUBMARINE
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 5000.0 AC ALL LOCATIONS
TTQY TERMINAL TYPE AND QUANTITY 6 CLIP
CPRL TRIP RELEASE CHARACTERISTIC INSTANTANEOUS ALL LOCATIONS
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 THREADED HOLE AND 6 CLIP
ADAU BODY HEIGHT 3.375 INCHES NOMINAL
ADTV CASE MATERIAL PLASTIC
CPRQ RESET METHOD MANUAL
AJEC BOSS HEIGHT 0.125 INCHES NOMINAL
THSD THREAD SERIES DESIGNATOR UNC
ZZZT NONDEFINITIVE SPEC/STD DATA AQB-A51 TYPE AND NQB-A51 TYPE
ADAQ BODY LENGTH 4.125 INCHES NOMINAL
FEAT SPECIAL FEATURES THE AQB-A51 IS A FORM, FIT AND FUNCTION REPLACEMENT FOR THE AQB-A50 CIRCUIT BREAKER WITH ENHANCED OVERCURRENT PROTECTION FEATURES
AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 1.125 INCHES NOMINAL
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
AAQL BODY STYLE MULTIPOLE-SINGLE ACTUATOR TYPE
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 500.0 AC ALL LOCATIONS
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 0.625 INCHES NOMINAL
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 50.0 AMPERES AC ALL LOCATIONS
ZZZK SPECIFICATION/STANDARD DATA 81349-MIL-C-17361/1A GOVERNMENT SPECIFICATION

Similar Parts

ETN-1205 , ETN1205 , 5925-01-511-0210 , 5925015110210 , 015110210