A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.

CAGE Information

Code Company
30086 SPD ELECTRICAL SYSTEMS INC

Federal Supply Class

Title

CIRCUIT BREAKERS

Inclusions:

INCLUDES CIRCUIT BREAKERS AND CUTOUTS.

Exclusions:

EXCLUDES RELAYS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 5.562 INCHES NOMINAL
BBRJ SPECIAL HANDLING FEATURE MAGNETIC
AXHR MOUNTING FACILITY TYPE AND QUANTITY 4 UNTHREADED HOLE
ADAQ BODY LENGTH 6.500 INCHES NOMINAL
FREQ FREQUENCY IN HERTZ 60.0 ALL LOCATIONS
BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE
CPRX ACTUATOR POSITION DESIGNATION AT POLE TWO
AKPX POLE QUANTITY 3
CPSF ADJUSTABLE TRIP SETTING CURRENT RANGE PER POLE IN AMPS +600.0/+700.0 AC ALL LOCATIONS
ADAU BODY HEIGHT 4.125 INCHES NOMINAL
AFJN FRAGILITY FACTOR MODERATELY RUGGED
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 15000.0 AC ALL LOCATIONS
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 140.0 ALL LOCATIONS
CSWP SWITCH VOLTAGE RATING AND TYPE IN VOLTS 120.0 AC AND 120.0 DC
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
FEAT SPECIAL FEATURES SHUNT TRIP
CPRL TRIP RELEASE CHARACTERISTIC INSTANTANEOUS ALL LOCATIONS
CSSX SWITCH CURRENT RATING AND TYPE IN AMPS 50.0 AC AND 50.0 DC
CPRZ AUXILIARY SWITCH FUNCTION AND QUANTITY 2 ALARM
AEGJ SWITCH CONTACT ARRANGEMENT SINGLE POLE, DOUBLE THROW
AEHA DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 1.375 INCHES NOMINAL
AJEC BOSS HEIGHT 0.188 INCHES NOMINAL
CBBL FEATURES PROVIDED ADJUSTABLE TRIP RELEASE
AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 1.375 INCHES NOMINAL
ADTV CASE MATERIAL PLASTIC
CQSM SWITCH LOCATION AND POSITION DESIGNATION INTERNAL AT POLE ONE AND INTERNAL AT POLE THREE
CRCF TRIP RELEASE AMBIENT TEMP RATING 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS
CPRQ RESET METHOD MANUAL
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 3.312 INCHES NOMINAL
AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.190 INCHES NOMINAL
TTQY TERMINAL TYPE AND QUANTITY 6 QUICK DISCONNECT, FEMALE
CPRJ TRIP RELEASE METHOD THERMAL-MAGNETIC ALL LOCATIONS
CPRW ACTUATOR FUNCTION TRIP-RESET
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
CRTK SWITCH TERMINAL TYPE WIRE LEAD
AAQL BODY STYLE MULTIPOLE-SINGLE ACTUATOR TYPE
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 600.0 AC ALL LOCATIONS
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED GENERAL PURPOSE
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 50.0 AMPERES AC ALL LOCATIONS
ADAT BODY WIDTH 4.125 INCHES NOMINAL