Item Name:
TERMINAL , STUD
Definition:
A TERMINAL, GENERALLY POSTLIKE, HAVING AN AXIAL PORTION OF ITS BODY DESIGNED FOR PROJECTING THROUGH OR INTO A PANEL, OR THE LIKE, FOR MOUNTING. REQUIRES THE USE OF TOOL(S) FOR ATTACHMENT OF WIRE. THE CONDUCTOR CONNECTION MAY BE INSULATED FROM THE MOUNTING. EXCLUDES TERMINAL, FEEDTHRU. SEE ALSO TERMINAL, QUICK DISCONNECT AND TERMINAL SET, QUICK DISCONNECT.
CAGE Information
Code | Company |
---|---|
30086 | SPD ELECTRICAL SYSTEMS INC |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
PRMT | PRECIOUS MATERIAL | SILVER |
ABET | THREAD LENGTH | 5.625 INCHES |
AGTA | BASIC SHAPE STYLE | NONTUBULAR, HEX |
PMLC | PRECIOUS MATERIAL AND LOCATION | OVERALL OUTER SURFACE SILVER |
SFTT | SURFACE TREATMENT | SILVER OVERALL SINGLE LAYER |
AALA | LARGEST DIAMETER | 0.760 INCHES SINGLE END |
ATGD | MOUNTING THREAD SERIES | UNF |
AALX | MOUNTING METHOD STYLE | STUD |
AAJT | OVERALL HEIGHT | 7.000 INCHES |
AALV | ELECTRICAL INSULATION FEATURE | UNINSULATED |
AAEY | TERMINAL LENGTH | 1.000 INCHES |
AAGW | WIDTH ACROSS FLATS | 1.375 INCHES |
CSFJ | CONDUCTOR ACCOMMODATION TYPE | PIN SINGLE END |
MATT | MATERIAL | COPPER OVERALL |
AAMP | MOUNTING THREAD DIAMETER | 1.000 INCHES |