Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
INSULATION SLEEVING , ELECTRICAL

Definition:

A RIGID OR FLEXIBLE TUBING HAVING UNIFORM INSIDE AND OUTSIDE DIAMETERS IN THE OVERALL LENGTH. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE TUBING, ITEMS IN BULK AND IN SPECIFIC FABRICATED LENGTHS (CUT TO SIZE). EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (AS MODIFIED); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; AND TUBING, NONMETALLIC.

CAGE Information

Code Company
92194 ALPHA WIRE CORP

Federal Supply Class

Title

ELECTRICAL INSULATORS AND INSULA

Inclusions:

INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
STYL STYLE DESIGNATOR SHRINKABLE
STYL STYLE DESIGNATOR SHRINKABLE
AFZM RECOVERED INSIDE DIAMETER 1.000 INCHES MAXIMUM
FLEX FLEXIBILITY FLEXIBLE
ABHP OVERALL LENGTH ANY ACCEPTABLE
AGAU HEAT SHRINKAGE RATING IN PERCENT 50.0
AARG RELIABILITY INDICATOR NOT ESTABLISHED
ABJH TEMP RATING -55.0 DEG CELSIUS AND 135.0 DEG CELSIUS
CQBC MINIMUM TENSILE STRENGTH 1500 POUNDS PER SQUARE INCH
UKBG DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS 500.0 VOLTS PER MIL /0.001 INCH/
AFZN RECOVERED WALL THICKNESS 0.038 INCHES MINIMUM AND 0.052 INCHES MAXIMUM
ADZC ENVIRONMENTAL PROTECTION MILDEW RESISTANT AND CORROSION RESISTANT AND WATER RESISTANT
MATL MATERIAL PLASTIC, POLYOLEFIN, MIL-I-23053/5, CLASS 2
HUES COLOR CLEAR
AFZL EXPANDED INSIDE DIAMETER 2.000 INCHES MINIMUM

Similar Parts

FIT221-2CLEAR , FIT2212CLEAR , 5970-00-089-1454 , 5970000891454 , 000891454