Part Number
Definition:
A RIGID OR FLEXIBLE TUBING HAVING UNIFORM INSIDE AND OUTSIDE DIAMETERS IN THE OVERALL LENGTH. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE TUBING, ITEMS IN BULK AND IN SPECIFIC FABRICATED LENGTHS (CUT TO SIZE). EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (AS MODIFIED); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; AND TUBING, NONMETALLIC.
CAGE Information
Code | Company |
---|---|
20999 | 3M CO ADMININISTRATIVE ELECTRONIC & |
Federal Supply Class
Title
ELECTRICAL INSULATORS AND INSULA
Inclusions:
INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
MATL | MATERIAL | PLASTIC, POLYOLEFIN, MIL-I-23053/5 |
HUES | COLOR | BLACK |
STYL | STYLE DESIGNATOR | SHRINKABLE |
CQBC | MINIMUM TENSILE STRENGTH | 2500 POUNDS PER SQUARE INCH |
FLEX | FLEXIBILITY | FLEXIBLE |
AGAU | HEAT SHRINKAGE RATING IN PERCENT | 50.0 |
UKBG | DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 1300.0 VOLTS PER MIL /0.001 INCH/ |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJH | TEMP RATING | -55.0 DEG CELSIUS AND 135.0 DEG CELSIUS |
AFZM | RECOVERED INSIDE DIAMETER | 0.250 INCHES NOMINAL |
AFZL | EXPANDED INSIDE DIAMETER | 0.500 INCHES NOMINAL |
AFZN | RECOVERED WALL THICKNESS | 0.025 INCHES NOMINAL |
ADZC | ENVIRONMENTAL PROTECTION | FLAME RESISTANT AND CORROSION RESISTANT AND MILDEW RESISTANT AND WEATHER RESISTANT |