Part Number
Part Number:
NSN:
NIIN:
Item Name:
CIRCUIT BREAKER
Definition:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.
CAGE Information
Code |
Company |
15605 |
EATON CORP OPNS & TECHNICAL CENTER |
Characteristics (Decoded)
MRC |
Requirements Statement |
Clear Text Reply |
CRCF |
TRIP RELEASE AMBIENT TEMP RATING |
80.0 DEG FAHRENHEIT NOMINAL ALL LOCATIONS |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
4 UNTHREADED HOLE |
FREQ |
FREQUENCY IN HERTZ |
60.0 ALL LOCATIONS |
CPRX |
ACTUATOR POSITION DESIGNATION |
AT POLE TWO |
AKPX |
POLE QUANTITY |
3 |
AJEC |
BOSS HEIGHT |
0.080 INCHES NOMINAL |
ADAQ |
BODY LENGTH |
6.125 INCHES NOMINAL |
AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
5.070 INCHES NOMINAL |
CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
14000.0 AC ALL LOCATIONS |
CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
CPRL |
TRIP RELEASE CHARACTERISTIC |
INSTANTANEOUS ALL LOCATIONS |
AGAV |
END ITEM IDENTIFICATION |
S.S.GENERATOR AND POWER SUPPLY SYSTEM ONBOARD 82 FT WPB CG VESSELS |
AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
1.375 INCHES NOMINAL |
AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.186 INCHES NOMINAL |
AEBQ |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH |
1.375 INCHES NOMINAL |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
100.0 AMPERES AC ALL LOCATIONS |
ADTV |
CASE MATERIAL |
PLASTIC |
CPRQ |
RESET METHOD |
MANUAL |
TTQY |
TERMINAL TYPE AND QUANTITY |
6 COMPRESSION |
AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
4.500 INCHES NOMINAL |
CPRJ |
TRIP RELEASE METHOD |
THERMAL-MAGNETIC ALL LOCATIONS |
CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
125.0 ALL LOCATIONS |
ADAU |
BODY HEIGHT |
3.420 INCHES NOMINAL |
CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT ALL LOCATIONS |
CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
1 TOGGLE |
AAQL |
BODY STYLE |
MULTIPOLE-SINGLE ACTUATOR TYPE |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
600.0 AC ALL LOCATIONS |
ADAT |
BODY WIDTH |
4.125 INCHES NOMINAL |
Similar Parts