Part Number
Part Number:
NSN:
NIIN:
Item Name:
SWITCH , THERMOSTATIC
Definition:
A SWITCH THAT IS ACTUATED BY CHANGES IN AMBIENT TEMPERATURE. EXCLUDES CIRCUIT BREAKER; CONTROL, TEMPERATURE (AS MODIFIED); FUSE (AS MODIFIED); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; AND THERMOSTAT, FLOW CONTROL. SEE ALSO CONTROL, TEMPERATURE (AS MODIFIED) AND REGULATOR, TEMPERATURE (AS MODIFIED).
CAGE Information
Code | Company |
---|---|
50306 | FEDERAL EQUIPMENT MANUFACTURING INC |
Federal Supply Class
Title
SWITCHES
Inclusions:
INCLUDES ROTARY, KNIFE, TOGGLE, PUSH BUTTON, MERCURY, THERMOSTATIC, AND DIFFERENTIAL PRESSURE SWITCHES.
Exclusions:
EXCLUDES SWITCHGEAR.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AEVT | CAPILLARY TUBE LENGTH | 72.000 INCHES NOMINAL |
AEVT | CAPILLARY TUBE LENGTH | 72.000 INCHES NOMINAL |
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
CTYM | CONTACT ADJUSTMENT RANGE | +70.00/+370.00 ACTUATION POINT DEGREES FAHRENHEIT |
AXGY | MOUNTING METHOD | BRACKET |
CSCF | TERMINAL TYPE | TAB, SOLDER LUG |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
AEVU | BULB LENGTH | 39.375 INCHES NOMINAL |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 480.0 AC AT SEA LEVEL SINGLE VOLTAGE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 1.500 INCHES NOMINAL |
CBBL | FEATURES PROVIDED | TUBING END SEAL CONNECTION |
AEVV | BULB DIAMETER | 0.375 INCHES NOMINAL |
CTHF | CONTACT LOAD CURRENT RATING | 15.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE |