Part Number
Part Number:
NSN:
NIIN:
Item Name:
CIRCUIT BREAKER
Definition:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.
CAGE Information
Code |
Company |
U6682 |
SELEX GALILEO LTD |
Characteristics (Decoded)
MRC |
Requirements Statement |
Clear Text Reply |
CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP ALL LOCATIONS |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
15.0 AMPERES AC ALL LOCATIONS |
FREQ |
FREQUENCY IN HERTZ |
50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
2000.0 AC ALL LOCATIONS |
AKPX |
POLE QUANTITY |
2 |
CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
10.000 MINIMUM AT 125 PCT ALL LOCATIONS AND 120.000 MAXIMUM AT 125 PCT ALL LOCATIONS |
THSD |
THREAD SERIES DESIGNATOR |
ISO M |
CQJX |
NOMINAL THREAD SIZE |
3.0 MILLIMETERS |
CPRX |
ACTUATOR POSITION DESIGNATION |
BETWEEN POLE ONE AND TWO |
AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
2.060 INCHES NOMINAL |
TTQY |
TERMINAL TYPE AND QUANTITY |
4 THREADED STUD |
CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
AEBQ |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH |
0.750 INCHES NOMINAL |
CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY ALL LOCATIONS |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
4 THREADED HOLE |
AJEC |
BOSS HEIGHT |
0.140 INCHES NOMINAL |
CPRQ |
RESET METHOD |
MANUAL |
CPRJ |
TRIP RELEASE METHOD |
MAGNETIC ALL LOCATIONS |
CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
125.0 ALL LOCATIONS |
CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
AGAV |
END ITEM IDENTIFICATION |
SEA DART MISSILE TEST EQUIPMENT |
ADAT |
BODY WIDTH |
1.859 INCHES NOMINAL |
ADTV |
CASE MATERIAL |
METAL |
AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
2.404 INCHES NOMINAL |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT ALL LOCATIONS |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
250.0 AC ALL LOCATIONS |
CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
1 TOGGLE |
ADAQ |
BODY LENGTH |
2.490 INCHES NOMINAL |
AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
1.940 INCHES NOMINAL |
AAQL |
BODY STYLE |
MULTIPOLE-SINGLE ACTUATOR TYPE |
AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
0.750 INCHES NOMINAL |
CQQR |
THREAD PITCH IN MILLIMETERS |
1.00 |