Part Number
Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
CAGE Information
Code | Company |
---|---|
71482 | CP CLARE CORP NORTH AMERICAN SALES O |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
AKDX | WINDING QUANTITY | 1 |
ABMK | OVERALL WIDTH | 1.230 INCHES NOMINAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.750 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE SINGLE MOUNTING FACILITY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
ABHP | OVERALL LENGTH | 2.500 INCHES NOMINAL |
APCN | COIL QUANTITY | 1 |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.625 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 2.500 INCHES NOMINAL |
AAJD | THREAD CLASS | 2B SINGLE MOUNTING FACILITY |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE MOUNTING FACILITY |
APNQ | ARC QUENCHING METHOD | AIR |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 62.5 AC |
APNP | DUTY TYPE | CONTINUOUS |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC RESISTIVE LOAD |
TTQY | TERMINAL TYPE AND QUANTITY | 4 PIN ALL FUNCTIONS |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |
AYSC | PILE-UP MAIN CONTACT FORM ARRANGEMENT | 1A |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
APNA | WINDING DC RESISTANCE RATING | 310.0 OHMS NOMINAL SINGLE WINDING |