Part Number
Part Number:
NSN:
NIIN:
Item Name:
CIRCUIT BREAKER
Definition:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.
CAGE Information
Code |
Company |
24930 |
ITT CORPORATION DBA ITT ELECTRONICS |
Characteristics (Decoded)
MRC |
Requirements Statement |
Clear Text Reply |
FREQ |
FREQUENCY IN HERTZ |
400.0 ALL LOCATIONS |
FREQ |
FREQUENCY IN HERTZ |
400.0 ALL LOCATIONS |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
10.0 AMPERES AC ALL LOCATIONS |
CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP ALL LOCATIONS |
BBRJ |
SPECIAL HANDLING FEATURE |
MAGNETIC |
PRMT |
PRECIOUS MATERIAL |
SILVER |
BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
CPRX |
ACTUATOR POSITION DESIGNATION |
AT POLE TWO |
AKPX |
POLE QUANTITY |
3 |
CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
1.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 5.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
1.678 INCHES NOMINAL |
THSD |
THREAD SERIES DESIGNATOR |
UNEF |
AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
300.0 AC ALL LOCATIONS |
PMLC |
PRECIOUS MATERIAL AND LOCATION |
CONTACT SURFACES SILVER |
CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
CQJX |
NOMINAL THREAD SIZE |
0.375 INCHES |
CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
130.0 ALL LOCATIONS |
CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY ALL LOCATIONS |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
240.0 AC ALL LOCATIONS |
CPRQ |
RESET METHOD |
MANUAL |
AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
0.875 INCHES NOMINAL |
ADAQ |
BODY LENGTH |
1.495 INCHES NOMINAL |
CPRJ |
TRIP RELEASE METHOD |
MAGNETIC-HYDRAULIC ALL LOCATIONS |
CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
FUNGUS RESISTANT AND HERMETICALLY SEALED AND MOISTURE RESISTANT |
ADAT |
BODY WIDTH |
1.872 INCHES NOMINAL |
ABXD |
BUSHING LENGTH |
0.375 INCHES NOMINAL |
CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
ADTV |
CASE MATERIAL |
METAL |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT ALL LOCATIONS |
AEBQ |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH |
0.625 INCHES NOMINAL |
PKWT |
UNPACKAGED UNIT WEIGHT |
4.500 OUNCES |
CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
1 TOGGLE |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
1 THREADED BUSHING W/PANEL SEAL |
AAQL |
BODY STYLE |
MULTIPOLE-SINGLE ACTUATOR TYPE |
CMLP |
THREAD QUANTITY PER INCH |
32 |
TTQY |
TERMINAL TYPE AND QUANTITY |
6 WIRE HOOK |
Similar Parts