Part Number
Part Number:
NSN:
NIIN:
Item Name:
INSULATION SLEEVING , ELECTRICAL , S
Definition:
A RIGID OR FLEXIBLE TUBING HAVING OTHER THAN UNIFORM FABRICATED SHAPES OR FORMS. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS OR BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE ITEMS. EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; AND INSULATION SLEEVING, ELECTRICAL.
CAGE Information
Code | Company |
---|---|
26512 | NORTHROP GRUMMAN SYSTEMS CORPORATION |
Federal Supply Class
Title
ELECTRICAL INSULATORS AND INSULA
Inclusions:
INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
HUES | COLOR | BLACK |
UKBG | DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 200.0 VOLTS PER MIL /0.001 INCH/ |
AGAH | MAIN BODY OVERALL LENGTH | 1.110 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAJ | MAIN BODY SMALL END INSIDE DIAMETER | 0.490 INCHES NOMINAL AS SUPPLIED |
AGAJ | MAIN BODY SMALL END INSIDE DIAMETER | 0.420 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
ADZC | ENVIRONMENTAL PROTECTION | FLAME RESISTANT AND MILDEW RESISTANT AND WATER RESISTANT |
ABJH | TEMP RATING | -55.0 DEG CELSIUS AND 125.0 DEG CELSIUS |
MATL | MATERIAL | PLASTIC, POLYOLEFIN, RT-301, RAYCHEM CORP |
CQBC | MINIMUM TENSILE STRENGTH | 1500 POUNDS PER SQUARE INCH |
FEAT | SPECIAL FEATURES | ADHESIVE COATED INSIDE SURFACE |
AGAH | MAIN BODY OVERALL LENGTH | 1.150 INCHES NOMINAL AS SUPPLIED |
AGAB | MAIN BODY WALL THICKNESS | 0.040 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
FLEX | FLEXIBILITY | SEMIRIGID |