Part Number
Part Number:
NSN:
NIIN:
Item Name:
PUMP UNIT , CENTRIFUGAL
Definition:
AN ASSEMBLED UNIT CONSISTING OF A COMMONLY MOUNTED CENTRIFUGAL PUMP(S), PRIME MOVER(S), AND THE NECESSARY COMPONENTS TO PROVIDE FOR A COMPLETE OPERATION.
CAGE Information
Code | Company |
---|---|
86329 | PARKER-HANNIFIN CORPORATION DBA FLUI |
Federal Supply Class
Title
POWER AND HAND PUMPS
Inclusions:
Exclusions:
EXCLUDES LABORATORY JET PUMPS (FSG 65 AND 66).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AHZF | CENTRIFUGAL PUMP IMPELLER QUANTITY | 1 |
ADZC | ENVIRONMENTAL PROTECTION | DUST-IGNITION PROOF |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AAXS | PRIME MOVER COOLING MEDIUM | AIR |
ASWT | INTAKE CONNECTION THREAD SIZE AND SERIES/TYPE DESIGNATOR | 1.062-12 UNJ |
AAYU | INTAKE CONNECTION TYPE | THREADED INTERNAL |
AHYW | DISCHARGE PRESSURE | 30.0 POUNDS PER SQUARE INCH GAGE |
CBBL | FEATURES PROVIDED | SELF-PRIMING |
AENC | PUMP QUANTITY | 1 |
ACDC | CURRENT TYPE | DC |
AKDJ | PRIME MOVER TYPE | ELECTRIC MOTOR |
AHZG | CENTRIFUGAL PUMP IMPELLER SUCTION TYPE | SINGLE |
AHYY | SUCTION LIFT | 20.000 FEET |
AAYW | DISCHARGE CONNECTION TYPE | THREADED INTERNAL |
AHYZ | OPERATING SPEED AT RATED CAPACITY | 1725.0 REVOLUTIONS PER MINUTE |
AHZA | PUMPING ELEMENT OPERATING POSITION | HORIZONTAL |
AAYT | INTAKE CONNECTION QUANTITY | 1 |
AENK | COOLING METHOD | AIR TO AIR COOLED |
ACKL | MEDIA FOR WHICH DESIGNED | HYDROCARBON FUELS AND OILS |
AAXH | PRIME MOVER QUANTITY | 1 |
AAYD | STAGE QUANTITY | 1 |
ASAZ | DISCHARGE CONNECTION THREAD SIZE AND SERIES/TYPE DESIGNATOR | 1.062-12 UNJ |
AHYX | TOTAL HEAD | 50.000 FEET |
AAYV | DISCHARGE CONNECTION QUANTITY | 1 |
AAXX | MOUNTING TYPE | BASE |
ELEC | VOLTAGE IN VOLTS | 24.0 |
AMPS | CURRENT RATING IN AMPS | 8.5 |
AHZE | CENTRIFUGAL PUMP DESIGN | RADIAL FLOW |
AHYV | MAXIMUM DISCHARGE FLOW RATE | 3.3 GALLONS PER MINUTE |