Part Number
Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
CAGE Information
Code | Company |
---|---|
94696 | SE RELAYS LLC MAGNECRAFT DIV SE RELA |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
AKDX | WINDING QUANTITY | 1 |
AAJD | THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 120.0 AC |
APNA | WINDING DC RESISTANCE RATING | 6.0 OHMS NOMINAL SINGLE WINDING |
ABKW | OVERALL HEIGHT | 1.469 INCHES NOMINAL |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
AJSS | FREQUENCY IN HERTZ | 60.0 NOMINAL |
APCN | COIL QUANTITY | 1 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED STUD SINGLE MOUNTING FACILITY |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE MOUNTING FACILITY |
ABHP | OVERALL LENGTH | 1.844 INCHES NOMINAL |
TTQY | TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |
APNP | DUTY TYPE | CONTINUOUS |
ABMK | OVERALL WIDTH | 1.688 INCHES NOMINAL |
ADZC | ENVIRONMENTAL PROTECTION | CORROSION PROOF |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 0.335 AMPERES AC SINGLE WINDING |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 6.0 VOLTS -80 DEG FAHRENHEIT TYPE 4F SINGLE WINDING |