Part Number
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
CAGE Information
Code | Company |
---|---|
80103 | VEECO INSTRUMENTS INC LAMBDA DIV |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABCX | BOARD CONSTRUCTION | SOLID CONSTRUCTION |
ABCX | BOARD CONSTRUCTION | SOLID CONSTRUCTION |
ABGS | BASE THICKNESS | 0.250 INCHES |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
ABGQ | BOARD OVERALL HEIGHT | 0.906 INCHES |
ABGN | BOARD OVERALL LENGTH | 3.656 INCHES |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.375 INCHES |
SFTT | SURFACE TREATMENT | TIN TERMINALS |
AMPS | CURRENT RATING IN AMPS | 15.0 |
CRZR | FEEDTHRU TERMINAL QUANTITY | 8 SINGLE COMBINATION |
AAMA | MOUNTING HOLE DIAMETER | 0.160 INCHES |
ABCS | TERMINAL ROW QUANTITY | 2 |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | MIL-M-14,TYPE CFG MIL SPEC SINGLE MATERIAL RESPONSE BOARD |
ABCU | DISTANCE BETWEEN TERMINAL ROW CENTERS | 0.312 INCHES |
CWLG | TERMINAL PATTERN ARRANGEMENT | SINGLE ROW |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.375 INCHES |
ABGP | BOARD OVERALL WIDTH | 0.875 INCHES |
MATT | MATERIAL | COPPER ALLOY TERMINALS |
CQCW | FEEDTHRU CONNECTION END TYPE | F8 SECOND END SINGLE COMBINATION |
ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 0.406 INCHES |
CWLN | TERMINAL DESIGN | VERTICAL FEEDTHRU |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.140 INCHES |
ABDV | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.312 INCHES |
MATT | MATERIAL | PLASTIC PHENOLIC BOARD AND CELLULOSE BOARD |
AAQL | BODY STYLE | BARRIER TYPE |