Part Number
Definition:
A RIGID OR FLEXIBLE TUBING HAVING UNIFORM INSIDE AND OUTSIDE DIAMETERS IN THE OVERALL LENGTH. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE TUBING, ITEMS IN BULK AND IN SPECIFIC FABRICATED LENGTHS (CUT TO SIZE). EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (AS MODIFIED); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; AND TUBING, NONMETALLIC.
CAGE Information
Code | Company |
---|---|
20999 | 3M CO ADMININISTRATIVE ELECTRONIC & |
Federal Supply Class
Title
ELECTRICAL INSULATORS AND INSULA
Inclusions:
INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AARX | INSIDE DIAMETER | 0.245 INCHES MINIMUM AND 0.260 INCHES MAXIMUM |
AARX | INSIDE DIAMETER | 0.245 INCHES MINIMUM AND 0.260 INCHES MAXIMUM |
FLEX | FLEXIBILITY | FLEXIBLE |
UKBG | DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 700.0 VOLTS PER MIL /0.001 INCH/ |
ABHP | OVERALL LENGTH | ANY ACCEPTABLE |
MATL | MATERIAL | PLASTIC, POLYVINYL CHLORIDE, MIL-I-631, TYPE F, FORM U, SUBFORM UB, GRADE A, CLASS 1 |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AAGT | WALL THICKNESS | 0.018 INCHES MINIMUM AND 0.023 INCHES MAXIMUM |
ZZZT | NONDEFINITIVE SPEC/STD DATA | A GRADE AND UB SUBFORM AND U FORM AND 1 CATEGORY AND 0.250IN. SIZE AND I CLASS AND F TYPE |
ADZC | ENVIRONMENTAL PROTECTION | FLAME RESISTANT AND MILDEW RESISTANT AND OIL RESISTANT |
STYL | STYLE DESIGNATOR | NONSHRINKABLE |
CQBC | MINIMUM TENSILE STRENGTH | 1800 POUNDS PER SQUARE INCH |
HUES | COLOR | WHITE |
ZZZX | DEPARTURE FROM CITED DESIGNATOR | AS MODIFIED BY COLOR |