Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
TRANSFORMER , CURRENT

Definition:

AN ITEM CONSISTING OF ONE OR MORE WINDINGS, DESIGNED TO BE PLACED NEAR OR CONNECTED IN SERIES WITH AN ALTERNATING CURRENT POWER LINE TO MEASURE THE CURRENT PASSING THROUGH THE LINE BY MEANS OF A METER; OR TO CONTROL THE CURRENT PASSING THROUGH THE LINE BY MEANS OF A CONTROL DEVICE. EXCLUDES TRANSFORMER, POWER, CURRENT REGULATING.

CAGE Information

Code Company
09969 VISHAY DALE ELECTRONICS INC. DIV VIS

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
TTQY TERMINAL TYPE AND QUANTITY 2 PIN
ABKW OVERALL HEIGHT 0.850 INCHES MINIMUM
AKPV MOUNTING FACILITY QUANTITY 2 SINGLE GROUP
CRBZ WINDING OPERATING CURRENT 20.0 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE PRIMARY
AGAV END ITEM IDENTIFICATION END ITEM C-17A
FEAT SPECIAL FEATURES THE DIAMETER OF HOLE FOR PRIMARY WIRE IS 0.075
ACZB FREQUENCY RATING 80.0 KILOHERTZ NOMINAL SINGLE COMPONENT
ABFE HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION SALT SPRAY RESISTANT AND MOISTURE RESISTANT AND VIBRATION RESISTANT
AARG RELIABILITY INDICATOR NOT ESTABLISHED
AEHZ MAXIMUM OPERATING TEMP 130.0 DEG CELSIUS
AKNA INCLOSURE TYPE HERMETICALLY SEALED
ABHP OVERALL LENGTH 0.615 INCHES MAXIMUM
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
AXGY MOUNTING METHOD PLUG-IN SINGLE GROUP
CRBZ WINDING OPERATING CURRENT 0.1 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE SECONDARY
ABMK OVERALL WIDTH 0.310 INCHES MAXIMUM
ADAU BODY HEIGHT 0.600 INCHES MAXIMUM

Similar Parts

ITP-1325-19 , ITP132519 , 5950-01-522-5482 , 5950015225482 , 015225482