Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
CIRCUIT BREAKER

Definition:

A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.

CAGE Information

Code Company
74193 EATON CORP HEINEMANN PRODUCTS COMMER

Federal Supply Class

Title

CIRCUIT BREAKERS

Inclusions:

INCLUDES CIRCUIT BREAKERS AND CUTOUTS.

Exclusions:

EXCLUDES RELAYS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 1.0 AMPERES AC ALL LOCATIONS AND 30.1 AMPERES DC ALL LOCATIONS
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 1.0 AMPERES AC ALL LOCATIONS AND 30.1 AMPERES DC ALL LOCATIONS
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC ALL LOCATIONS AND 24.0 DC ALL LOCATIONS
FREQ FREQUENCY IN HERTZ 60.0 ALL LOCATIONS
TTQY TERMINAL TYPE AND QUANTITY 4 QUICK DISCONNECT, MALE
AKPX POLE QUANTITY 2
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC ALL LOCATIONS AND 2000.0 DC ALL LOCATIONS
AXHR MOUNTING FACILITY TYPE AND QUANTITY 4 THREADED BUSHING
ADAQ BODY LENGTH 2.188 INCHES NOMINAL
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 1.188 INCHES NOMINAL
CPRL TRIP RELEASE CHARACTERISTIC INSTANTANEOUS ALL LOCATIONS
ADAT BODY WIDTH 0.760 INCHES NOMINAL
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 2.312 INCHES NOMINAL
ADTV CASE MATERIAL PLASTIC
CPRQ RESET METHOD MANUAL
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.438 INCHES NOMINAL
THSD THREAD SERIES DESIGNATOR UNC
CPSM INTERNAL TRIP RELEASE CONFIGURATION RELAY TRIP ALL LOCATIONS
CPRJ TRIP RELEASE METHOD MAGNETIC-HYDRAULIC ALL LOCATIONS
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 ALL LOCATIONS
ABXD BUSHING LENGTH 0.375 INCHES NOMINAL
CPRW ACTUATOR FUNCTION TRIP-RESET
CPRX ACTUATOR POSITION DESIGNATION AT EACH POLE
CQJX NOMINAL THREAD SIZE 0.164 INCHES
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.625 INCHES NOMINAL
AAQL BODY STYLE MULTIPOLE-SINGLE ACTUATOR TYPE
CPRY EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE AND TWO LINKED

Similar Parts

JA2A0B6 , JA2A0B6 , 5925-00-163-0998 , 5925001630998 , 001630998