Part Number
Definition:
TWO OR MORE INSULATED CONDUCTORS (SOLID OR STRANDED) CONTAINED IN A COMMON COVERING, OR TWO OR MORE INSULATED CONDUCTORS TWISTED OR MOLDED TOGETHER WITHOUT A COMMON COVERING, OR ONE INSULATED CONDUCTOR WITH A METALLIC COVERING, COVERING, SHIELD, OR OUTER CONDUCTOR. THE RATED WORKING VOLTAGE OF THE ITEM MUST BE 300 VOLTS OR MORE, OR IN LIEU OF THIS THE TEST VOLTAGE MUST BE 1,000 VOLTS OR MORE; AND THE SIZE OF EACH INDIVIDUAL CONDUCTOR MUST BE NUMBER 18 AMERICAN WIRE GAGE (0.75 SQUARE MILLIMETERS) OR LARGER. FOR CABLES WITH UNINSULATED NEUTRAL CONDUCTOR USE THE HIGHTEST RATED VOLTAGE. REFERS TO BULK QUANTITIES ONLY, FOR ITEMS OF DEFINITE LENGTH WITH PROCESSED ENDS OR TERMINATED IN FITTINGS, SEE CABLE ASSEMBLY, POWER, ELECTRICAL. FOR LOW VOLTAGE AIRCRAFT AND AUTOMOTIVE CABLE, SEE CABLE, SPECIAL PURPOSE, ELECTRICAL.
CAGE Information
Code | Company |
---|---|
58905 | STRIKE WEAPONS AND UNMANNED AVIATION |
Federal Supply Class
Title
WIRE AND CABLE, ELECTRICAL
Inclusions:
INCLUDES INSULATED AND NONINSULATED, WIRE AND CABLE, SUCH AS, ANTENNA WIRE, COAXIAL CABLE, FUSE AND RESISTANCE WIRE, AND MAGNET WIRE.
Exclusions:
EXCLUDES RADIO FREQUENCY TRANSMISSION LINE (FSC 5985); FIBER OPTIC CABLE (FSC 6015); COMMUNICATION CABLE ASSEMBLIES (FSC 5995); DISTRIBUTION AND POWER TRANSMISSION CABLE ASSEMBLIES (FSC 6150).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | ROUND |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | ASTM B33 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
CXFG | CONDUCTOR SEQUENCE WITHIN GROUPS | FOURTH CONDUCTOR SECOND GROUP AND FIFTH CONDUCTOR SECOND GROUP AND SIXTH CONDUCTOR SECOND GROUP |
FEAT | SPECIAL FEATURES | FIFTH GROUPING ARRANGEMENT ELEVENTH AND TWELFTH CONDUCTOR THROUGH EIGHT GROUPING ARRANGEMENT SEVENTEENTH AND EIGHTEENTH CONDUCTOR |
CXFK | VOLTAGE RATING | 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS |
CXFG | CONDUCTOR SEQUENCE WITHIN GROUPS | SEVENTH CONDUCTOR THIRD GROUP AND EIGHTH CONDUCTOR THIRD GROUP |
STDC | SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | ASTM B33-63 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
CXDC | ROUND CONDUCTOR SIZE | 16 AWG ALL CONDUCTORS |
SFTT | SURFACE TREATMENT | TIN CORE CONDUCTOR ALL CONDUCTORS |
CXCW | CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
CXDQ | CONDUCTOR ARRANGEMENT AND QUANTITY | 2 TRIPLES AND 6 TWISTED PAIR |
CXDG | STRAND AWG SIZE PER CONDUCTOR | 29 ALL CONDUCTORS |
MATT | MATERIAL | COPPER ALLOY 101 CORE CONDUCTOR ALL CONDUCTORS OR COPPER ALLOY 102 CORE CONDUCTOR ALL CONDUCTORS |
AMQN | CONDUCTOR QUANTITY | 18 |
ADVL | CROSS SECTION OUTSIDE DIAMETER | 0.900 INCHES NOMINAL |
BLNZ | STRAND QUANTITY PER CONDUCTOR | 19 ALL CONDUCTORS |
ABJH | TEMP RATING | 75.0 DEG CELSIUS |
CXFG | CONDUCTOR SEQUENCE WITHIN GROUPS | FIRST CONDUCTOR FIRST GROUP AND SECOND CONDUCTOR FIRST GROUP AND THIRD CONDUCTOR FIRST GROUP |
CXFG | CONDUCTOR SEQUENCE WITHIN GROUPS | NINTH CONDUCTOR FOURTH GROUP AND TENTH CONDUCTOR FOURTH GROUP |
AWXS | COLOR CODING DOCUMENT | JCM-15480-58905 DRAWING |