Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC

Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

CAGE Information

Code Company
02032 HOLLINGSWORTH JOHN R CO

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
TTQY TERMINAL TYPE AND QUANTITY 2 SCREW CONTACTS
AKDX WINDING QUANTITY 1
TTQY TERMINAL TYPE AND QUANTITY 2 SCREW ENERGIZING ELEMENT
APNA WINDING DC RESISTANCE RATING 1.2 KILOHMS NOMINAL SINGLE WINDING
ABHP OVERALL LENGTH 2.500 INCHES NOMINAL
AJSS FREQUENCY IN HERTZ 60.0 NOMINAL
APCN COIL QUANTITY 1
ABMK OVERALL WIDTH 2.500 INCHES NOMINAL
AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.187 INCHES NOMINAL SINGLE MOUNTING FACILITY
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.875 INCHES NOMINAL SINGLE MOUNTING FACILITY
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY
APNP DUTY TYPE CONTINUOUS
ABKW OVERALL HEIGHT 2.000 INCHES NOMINAL
CQYJ MOUNTING FACILITY PATTERN IN-LINE SINGLE MOUNTING FACILITY
CRPQ NOMINAL OPERATING CURRENT RATING AND TYPE 43.0 MILLIAMPERES AC SINGLE WINDING
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 240.0 VOLTS -80 DEG FAHRENHEIT TYPE 4F SINGLE WINDING
AGAV END ITEM IDENTIFICATION ENGINE GENERATOR (EG)

Similar Parts

JHP124-055 , JHP124055 , 5945-01-033-6387 , 5945010336387 , 010336387