Item Name:
RELAY , ELECTROMAGNETIC

Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

CAGE Information

Code Company
02032 HOLLINGSWORTH JOHN R CO

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKDX WINDING QUANTITY 1
AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.156 INCHES NOMINAL SINGLE MOUNTING FACILITY
ABHP OVERALL LENGTH 2.594 INCHES NOMINAL
TTQY TERMINAL TYPE AND QUANTITY 2 TAB, SOLDER LUG ENERGIZING ELEMENT
ABKW OVERALL HEIGHT 1.500 INCHES NOMINAL
AJSS FREQUENCY IN HERTZ 60.0 NOMINAL
TTQY TERMINAL TYPE AND QUANTITY 6 TAB, SOLDER LUG CONTACTS
APCN COIL QUANTITY 1
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 115.0 VOLTS -80 DEG FAHRENHEIT TYPE 4F SINGLE WINDING
ABMK OVERALL WIDTH 1.812 INCHES NOMINAL
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 24.0 AC
APNP DUTY TYPE CONTINUOUS
CRNG NONPILE-UP MAIN CONTACT ARRANGEMENT 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
CQYJ MOUNTING FACILITY PATTERN IN-LINE SINGLE MOUNTING FACILITY
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 2.250 INCHES NOMINAL SINGLE MOUNTING FACILITY
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 15.0 AMPERES AC RESISTIVE LOAD
AGAV END ITEM IDENTIFICATION ENGINE GENERATOR (EG)

Similar Parts