Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC

Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

CAGE Information

Code Company
02032 HOLLINGSWORTH JOHN R CO

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKDX WINDING QUANTITY 1
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 300.0 AC
TTQY TERMINAL TYPE AND QUANTITY 2 TAB, SOLDER LUG CONTACTS
TTQY TERMINAL TYPE AND QUANTITY 2 SCREW ENERGIZING ELEMENT
ADZC ENVIRONMENTAL PROTECTION DUSTPROOF
AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.188 INCHES NOMINAL SINGLE MOUNTING FACILITY
APCN COIL QUANTITY 1
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 10.0 AMPERES AC RESISTIVE LOAD
CRNG NONPILE-UP MAIN CONTACT ARRANGEMENT 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
ABHP OVERALL LENGTH 2.875 INCHES NOMINAL
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 2.438 INCHES NOMINAL SINGLE MOUNTING FACILITY
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 32.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING
ABKW OVERALL HEIGHT 3.000 INCHES NOMINAL
APNP DUTY TYPE CONTINUOUS
ABMK OVERALL WIDTH 1.500 INCHES NOMINAL
CQYJ MOUNTING FACILITY PATTERN IN-LINE SINGLE MOUNTING FACILITY
AGAV END ITEM IDENTIFICATION ENGINE GENERATOR (EG)

Similar Parts