Part Number
Definition:
A RESISTOR IN WHICH A SLIDING OR ROLLING CONTACT MOVES OVER AN EXPOSED AREA OF THE RESISTIVE ELEMENT TO CHANGE THE OHMIC VALUE OF THE OUTPUT. THE FUNCTIONAL TOLERANCE (LINEARITY), IF GIVEN, OF THE OUTPUT IS GREATER THAN PLUS OR MINUS 1 PERCENT ON LINEAR OUTPUTS. SPECIFIED OUTPUTS SUCH AS SINE, COSINE, TANGENT, ETC., SHALL BE CONSIDERED TO BE PRECISION. FOR ITEMS HAVING MANUALLY POSITIONED TAPS DESIGNED TO BE SET AND FIXED PRIOR TO USE, SEE RESISTOR, ADJUSTABLE. FOR ITEMS WITH STEP BY STEP VARIATION, SEE RHEOSTAT AND RESISTOR, STEP BY STEP. FOR TANDEM-MOUNTED ITEMS DESIGNED TO FUNCTION TOGETHER AS AN ATTENUATOR (AND RATED ACCORDINGLY), SEE ATTENUATOR, VARIABLE. EXCLUDES RESISTOR (1), VARIABLE, WIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND PRECISION; AND RESISTOR (1), VARIABLE, WIRE WOUND, PRECISION.
CAGE Information
Code | Company |
---|---|
01121 | ROCKWELL AUTOMATION INC. |
Federal Supply Class
Title
RESISTORS
Inclusions:
INCLUDES VARISTORS; RESISTIVE BALLAST TUBES; RHEOSTATS; RESISTOR NETWORKS; RESISTOR MOUNTING HARDWARE; THERMISTORS.
Exclusions:
EXCLUDES RESISTANCE WIRE.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
TTQY | TERMINAL TYPE AND QUANTITY | 6 TAB, SOLDER LUG |
TTQY | TERMINAL TYPE AND QUANTITY | 6 TAB, SOLDER LUG |
AEDX | SHAFT STYLE | ROUND |
AEFL | MAXIMUM RUNNING TORQUE | 1.00 INCH-OUNCES |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | STOPS |
AJYP | SCREW THREAD SERIES DESIGNATOR | UNEF |
AEFK | MAXIMUM STARTING TORQUE | 6.00 INCH-OUNCES |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 120.0 ALL SECTIONS |
AAPN | SECTION QUANTITY | 2 |
AEFN | NONTURN DEVICE LOCATION | AT 9 OCLOCK |
ADAQ | BODY LENGTH | 1.406 INCHES MAXIMUM |
AEFD | ACTUATOR TYPE | DUAL CONCENTRIC |
ADAP | MOUNTING BUSHING LENGTH | 0.406 INCHES NOMINAL |
APXH | TERMINAL LOCATION | RADIALLY POSITIONED OVER LESS THAN HALF THE CIRCUMFERENCE |
AEFM | MAXIMUM STOP TORQUE | 192.00 INCH-OUNCES |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 2.0 FREE AIR ALL SECTIONS |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -10.0/+10.0 ALL SECTIONS |
CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 312.0 NOMINAL |
AEFH | EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 312.0 NOMINAL |
AXGY | MOUNTING METHOD | SHAFT AND STANDARD BUSHING |
AAQL | BODY STYLE | CYLINDRICAL BUSHING MOUNTED |
AJYQ | SCREW THREAD QUANTITY PER INCH | 32.0 |
ABXF | SHAFT LENGTH | 0.906 INCHES MINIMUM AND 1.406 INCHES MAXIMUM |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 250.0 KILOHMS ALL SECTIONS |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 70.0 ALL SECTIONS |
ABWV | SHAFT DIAMETER | 0.125 INCHES MINIMUM AND 0.250 INCHES MAXIMUM |
ADAV | OVERALL DIAMETER | 1.484 INCHES MAXIMUM |
AEFP | NONTURN DEVICE RADIUS | 0.531 INCHES NOMINAL |
ABPM | BODY DIAMETER | 1.156 INCHES MAXIMUM |
CSDL | STANDARD TAPER CURVE PER SECTION | A ALL SECTIONS |
CQDB | RESISTANCE TEMP CHARACTERISTIC RANGE PER SECTION IN PERCENT | +0.0/+8.0 -55 DEG CELSIUS ALL SECTIONS AND -3.0/+3.0 85 DEG CELSIUS ALL SECTIONS AND +0.0/+2.0 0 DEG CELSIUS ALL SECTIONS AND -0.0/+0.0 25 DEG CELSIUS ALL SECTIONS AND +0.0/+4.0 -25 DEG CELSIUS ALL SECTIONS AND +0.0/+6.0 120 DEG CELSIUS ALL SECTIONS |
ABHP | OVERALL LENGTH | 2.828 INCHES MAXIMUM |
AJYN | SCREW THREAD DIAMETER | 0.375 INCHES NOMINAL |