Part Number
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
CAGE Information
Code | Company |
---|---|
26405 | MARATHON SPECIAL PRODUCTS CORPORATIO |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
AMPS | CURRENT RATING IN AMPS | 15.0 |
STDC | SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | QQ-N-290,CLASS 1,TYPE 8 FED SPEC 1ST TREATMENT RESPONSE TERMINALS |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.406 INCHES |
CRZR | FEEDTHRU TERMINAL QUANTITY | 8 SINGLE COMBINATION |
CQCZ | TERMINAL CONNECTING LINK QUANTITY | 8 SINGLE |
AAPB | DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 4000.0 |
ABCU | DISTANCE BETWEEN TERMINAL ROW CENTERS | 0.500 INCHES |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | MIL-P-19833,TYPE GDI-30F MIL SPEC SINGLE MATERIAL RESPONSE BOARD |
CQCW | FEEDTHRU CONNECTION END TYPE | F4 15TH MATERIAL RESPONSE BOTH ENDS |
ABCS | TERMINAL ROW QUANTITY | 2 |
CWLG | TERMINAL PATTERN ARRANGEMENT | MULTI-ROW |
ABGP | BOARD OVERALL WIDTH | 1.312 INCHES |
CQCW | FEEDTHRU CONNECTION END TYPE | 857 FOURTH COMBINATION BOTH ENDS |
CSCR | TERMINAL CONNECTING LINK TYPE | 1 SINGLE |
ABGN | BOARD OVERALL LENGTH | 5.500 INCHES |
AAMA | MOUNTING HOLE DIAMETER | 0.228 INCHES |
CWLN | TERMINAL DESIGN | LINKED VERTICAL FEEDTHRU |
ABGQ | BOARD OVERALL HEIGHT | 1.328 INCHES |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.562 INCHES |
ABDV | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.500 INCHES |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 5.062 INCHES |
MATT | MATERIAL | PLASTIC DIALLYL PHTHALATE BOARD AND GLASS FIBER BOARD |
ABCX | BOARD CONSTRUCTION | HOLLOW CONSTRUCTION WITHOUT INSULATED STRIP |
ABGS | BASE THICKNESS | 0.453 INCHES |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.203 INCHES |
ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 0.703 INCHES |
SFTT | SURFACE TREATMENT | NICKEL TERMINALS AND TIN TERMINALS |
AAQL | BODY STYLE | BARRIER TYPE |