Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
FILTER , RADIO FREQUENCY INTERFERE

Definition:

AN ITEM DESIGNED TO SUPPRESS UNDESIRED (INTERFERING) FREQUENCIES AND HAVE A MINIMAL EFFECT ON THE DESIRED FREQUENCIES WHEN INSERTED IN AN ELECTRICAL POWER CIRCUIT. EXCLUDES ITEMS WHICH CONSIST OF A SINGLE CAPACITOR, INDUCTOR, RESISTOR, OR DEVICES CONSISTING OF ONLY TWO OR MORE CIRCUIT ELEMENTS OF THE SAME BASIC NAME. EXCLUDES FILTER, LOW PASS AND SUPPRESSOR, IGNITION INTERFERENCE. FOR ITEMS DESIGNED TO BE INSERTED IN A LINE WHICH IS PRIMARILY INTENDED TO CARRY HIGH FREQUENCY WAVES MODULATED WITH SIGNALS, SUCH AS ANTENNA LEAD-IN, SEE FILTER, BAND SUPPRESSION AND FILTER, BAND PASS. SEE ALSO LIMITER, ELECTRICAL NOISE.

CAGE Information

Code Company
56289 SPRAGUE ELECTRIC CO WORLD HQS

Federal Supply Class

Title

FILTERS AND NETWORKS

Inclusions:

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CQDW FUNCTIONAL TERMINAL TYPE AND QUANTITY 3 THREADED STUD OUTPUT
AHBL PRINCIPAL CIRCUITRY TYPE PER FUNCTION INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE
CQGC OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 440.0 VOLTS AC 1ST RADIO INTERFERENCE
CQGC OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 440.0 VOLTS AC 2ND RADIO INTERFERENCE
AECR VIBRATION RESISTANCE RANGE IN HERTZ +10.0/+55.0
CQGC OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 440.0 VOLTS AC 3RD RADIO INTERFERENCE
AHBB POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 60.0 1ST RADIO INTERFERENCE
AHBL PRINCIPAL CIRCUITRY TYPE PER FUNCTION INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE
AHBE MAXIMUM VOLTAGE DROP PER FUNCTION 1.0 VOLTS AC 1ST RADIO INTERFERENCE
AHBB POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 60.0 2ND RADIO INTERFERENCE
CQDW FUNCTIONAL TERMINAL TYPE AND QUANTITY 3 THREADED STUD INPUT
AHBB POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 60.0 3RD RADIO INTERFERENCE
AHBC OPERATING CURRENT RATING PER FUNCTION IN AMPS 80.0 1ST RADIO INTERFERENCE
AHBC OPERATING CURRENT RATING PER FUNCTION IN AMPS 80.0 2ND RADIO INTERFERENCE
AHBC OPERATING CURRENT RATING PER FUNCTION IN AMPS 80.0 3RD RADIO INTERFERENCE
AFGA OPERATING TEMP RANGE -55.0/+85.0 DEG CELSIUS
AHBE MAXIMUM VOLTAGE DROP PER FUNCTION 1.0 VOLTS AC 2ND RADIO INTERFERENCE
AHBL PRINCIPAL CIRCUITRY TYPE PER FUNCTION INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE
AKNA INCLOSURE TYPE ENCASED
AHBE MAXIMUM VOLTAGE DROP PER FUNCTION 1.0 VOLTS AC 3RD RADIO INTERFERENCE

Similar Parts

JN14-1538A , JN141538A , 5915-00-891-8641 , 5915008918641 , 008918641