Part Number
Part Number:
NSN:
NIIN:
Item Name:
FILTER , RADIO FREQUENCY INTERFERE
Definition:
AN ITEM DESIGNED TO SUPPRESS UNDESIRED (INTERFERING) FREQUENCIES AND HAVE A MINIMAL EFFECT ON THE DESIRED FREQUENCIES WHEN INSERTED IN AN ELECTRICAL POWER CIRCUIT. EXCLUDES ITEMS WHICH CONSIST OF A SINGLE CAPACITOR, INDUCTOR, RESISTOR, OR DEVICES CONSISTING OF ONLY TWO OR MORE CIRCUIT ELEMENTS OF THE SAME BASIC NAME. EXCLUDES FILTER, LOW PASS AND SUPPRESSOR, IGNITION INTERFERENCE. FOR ITEMS DESIGNED TO BE INSERTED IN A LINE WHICH IS PRIMARILY INTENDED TO CARRY HIGH FREQUENCY WAVES MODULATED WITH SIGNALS, SUCH AS ANTENNA LEAD-IN, SEE FILTER, BAND SUPPRESSION AND FILTER, BAND PASS. SEE ALSO LIMITER, ELECTRICAL NOISE.
CAGE Information
Code | Company |
---|---|
56289 | SPRAGUE ELECTRIC CO WORLD HQS |
Federal Supply Class
Title
FILTERS AND NETWORKS
Inclusions:
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 300.0 MILLIVOLTS DC 1ST RADIO INTERFERENCE |
TEST | TEST DATA DOCUMENT | 72314-1076-642 DRAWING |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 TAB, SOLDER LUG OUTPUT |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 750.0 MILLIVOLTS AC 2ND RADIO INTERFERENCE |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.730 INCHES MINIMUM AND 0.770 INCHES MAXIMUM |
CQRG | BODY MATERIAL | METAL |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 2.0 1ST RADIO INTERFERENCE |
ADAU | BODY HEIGHT | 1.480 INCHES MINIMUM AND 2.020 INCHES MAXIMUM |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 28.0 VOLTS DC 1ST RADIO INTERFERENCE |
AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
ADAT | BODY WIDTH | 1.100 INCHES MINIMUM AND 1.140 INCHES MAXIMUM |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
AFGA | OPERATING TEMP RANGE | -55.0/+85.0 DEG CELSIUS |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.600 INCHES MINIMUM AND 1.640 INCHES MAXIMUM |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 2.0 2ND RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 TAB, SOLDER LUG INPUT |
ADAQ | BODY LENGTH | 2.480 INCHES MINIMUM AND 2.520 INCHES MAXIMUM |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 2ND RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |