Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
BALANCING MACHINE , DYNAMIC-STATIC

Definition:

A MACHINE DESIGNED TO ACCURATELY MEASURE AND LOCATE THE AMOUNT OF STATIC OR DYNAMIC UNBALANCE, OR THE COMBINED EFFECTS OF STATIC AND DYNAMIC UNBALANCE, IN ARBITRARILY SELECTED PLANES OF CORRECTION, IN GYRO-ROTORS OR THE ROTOR AND MAGNET ASSEMBLIES OF GYRO-STABILIZED INSTRUMENTS.

CAGE Information

Code Company
30218 SCHENCK CORPORATION

Federal Supply Class

Title

PHYSICAL PROPERTIES TESTING AND

Inclusions:

INCLUDES DESTRUCTIVE AND NONDESTRUCTIVE INSPECTION EQUIPMENT SUCH AS FLUORESCENT PENETRANT INSPECTION UNITS; MAGNETIC INSPECTION UNITS; INDUSTRIAL X-RAY MACHINES; INDUSTRIAL X-RAY FILM; TENSIOMETERS; MATERIAL HARDNESS TESTERS.

Exclusions:

EXCLUDES GENERAL PURPOSE MEASURING TOOLS (FSC 5210) AND PRECISION MEASURING TOOLS AND INSPECTION GAGES (FSC 5220).

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AGAV END ITEM IDENTIFICATION 6605-01-252-9480,NAVIGATION UNIT,INERTIAL
ATMN ANGULAR UNBALANCE LOCATION METHOD STROBOGLOW LAMP
AAXX MOUNTING TYPE BENCH
FTLD FUNCTIONAL DESCRIPTION PERFORMS STATIC BALANCING OF GIMBAL AXES OF THE INERTIAL PLATFORM P/N K140A035-01. MTBF 8,237 HOURS; DETERMINES VIBRATIONS AS SMALL AS ONE QUARTER OF ONE MILLIONTH OF AN INCH
ATMY INTEGRAL CORRECTION DRILLING ATTACHMENT INCLUDED

Similar Parts

K , K , 6635-00-986-6404 , 6635009866404 , 009866404