Part Number
Definition:
AN ENCLOSURE WHICH INCLUDES, MOUNTS, AND PROTECTS ONE OR MORE CIRCUIT BREAKERS. IT IS DESIGNED FOR AND MAY INCLUDE A COVER AND SUCH ACCESSORIES AS MOUNTING HARDWARE, BRACKETS, AND CONDUIT FITTINGS. MAY INCLUDE TERMINAL BOARDS AND/OR BUS CONDUCTORS USED AS A CONVENIENCE FOR TERMINATING THE CIRCUIT BREAKERS. MAY INCLUDE HANDLE TIE BARS. IT IS USUALLY USED AS A LOAD CENTER FOR THE PROTECTION OF CERTAIN ELECTRICAL DEVICES SUCH AS WATER HEATERS, MOTORS, ETC., OR AS A SERVICE CENTER FOR HOMES OR OFFICES. FOR BOXES WHICH INCLUDE ONLY SWITCHES, JACKS, FUSEHOLDERS, TERMINALS AND/OR TERMINAL BOARDS OR FUSEHOLDERS, OR ANY COMBINATION OF THESE DEVICES, SEE SWITCH BOX; JACK BOX; TERMINAL BOX; AND DISTRIBUTION BOX. FOR BOXES DESIGNED TO MOUNT AND PROTECT BUT DO NOT INCLUDE CIRCUIT BREAKERS, SEE CIRCUIT BREAKER BOX SUBASSEMBLY. SEE ALSO INTERCONNECTING CABINET; PANEL, POWER DISTRIBUTION; JUNCTION BOX; AND CABINET, ELECTRICAL EQUIPMENT.
CAGE Information
Code | Company |
---|---|
14280 | SCHNEIDER ELECTRIC USA, INC. DBA SCH |
Federal Supply Class
Title
CIRCUIT BREAKERS
Inclusions:
INCLUDES CIRCUIT BREAKERS AND CUTOUTS.
Exclusions:
EXCLUDES RELAYS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABKW | OVERALL HEIGHT | 21.375 INCHES NOMINAL |
BGJR | CIRCUIT BREAKER MANUFACTURER CODE | 60969 |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CDPF | CIRCUIT BREAKER NATIONAL STOCK NUMBER | 5925-01-130-8420 |
BFYD | MAIN LINE MAXIMUM AC VOLTAGE RATING IN VOLTS | 600.0 |
ABFY | OVERALL DEPTH | 6.312 INCHES NOMINAL |
AEBW | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 20.000 INCHES NOMINAL |
AGEJ | SYSTEM FOR WHICH DESIGNED | THREE WIRE THREE PHASE |
BGJL | CIRCUIT BREAKER TYPE AND QUANTITY | 1 TRIPLE POLE |
MATT | MATERIAL | STEEL |
CBBL | FEATURES PROVIDED | COVER |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.250 INCHES NOMINAL |
BFYC | MAIN LINE MAXIMUM CURRENT RATING IN AMPS | 175.0 |
AESL | STANDARD MOUNTING PATTERN DESIGNATOR | 4 POINT-RECTANGULAR |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 19.000 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 20.344 INCHES NOMINAL |
BGJQ | CIRCUIT BREAKER IDENTIFICATION | TFJ236175WL |
BGJM | CIRCUIT BREAKER CURRENT RATING IN AMPS | 600.0 |
STYL | STYLE DESIGNATOR | SQUARE, SURFACE MOUNTING |
AXGY | MOUNTING METHOD | UNTHREADED HOLE |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | GENERAL PURPOSE-NEMA TYPE 1 |