CIRCUIT BREAKER

Definition:

A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.

CAGE Information

Code Company
04429 SQUARE D CO LEEDS MFG PLANT

Federal Supply Class

Title

CIRCUIT BREAKERS

Inclusions:

INCLUDES CIRCUIT BREAKERS AND CUTOUTS.

Exclusions:

EXCLUDES RELAYS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
ADAQ BODY LENGTH 5.999 INCHES NOMINAL
FREQ FREQUENCY IN HERTZ 60.0 ALL LOCATIONS
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 200.0 ALL LOCATIONS
BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE
CQSM SWITCH LOCATION AND POSITION DESIGNATION EXTERNAL AT POLE TWO
CPRX ACTUATOR POSITION DESIGNATION AT POLE TWO
CRTK SWITCH TERMINAL TYPE BUS BAR
ADAU BODY HEIGHT 3.000 INCHES NOMINAL
CQJX NOMINAL THREAD SIZE 0.938 INCHES
AKPX POLE QUANTITY 3
AFJN FRAGILITY FACTOR MODERATELY RUGGED
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE NONTRIP FREE
CSSX SWITCH CURRENT RATING AND TYPE IN AMPS 10.0 AC
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 150.0 AMPERES AC ALL LOCATIONS
CSWP SWITCH VOLTAGE RATING AND TYPE IN VOLTS 120.0 AC
CPRZ AUXILIARY SWITCH FUNCTION AND QUANTITY 1 CONTROL
AXHR MOUNTING FACILITY TYPE AND QUANTITY 4 THREADED STUD
AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 1.500 INCHES NOMINAL
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 10000.0 AC ALL LOCATIONS
THSD THREAD SERIES DESIGNATOR UNS
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 40.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 125.000 MAXIMUM AT 200 PCT ALL LOCATIONS
AEGJ SWITCH CONTACT ARRANGEMENT SINGLE POLE, DOUBLE THROW
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 6.000 INCHES NOMINAL
ADTV CASE MATERIAL PLASTIC
CPRQ RESET METHOD MANUAL
AJEC BOSS HEIGHT 0.125 INCHES NOMINAL
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 PUSH BUTTON
TTQY TERMINAL TYPE AND QUANTITY 3 THREADED STUD
CPRJ TRIP RELEASE METHOD THERMAL-MAGNETIC ALL LOCATIONS
CPRW ACTUATOR FUNCTION TRIP-RESET
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 5.124 INCHES NOMINAL
APNQ ARC QUENCHING METHOD MAGNETIC BLOWOUT
CRCF TRIP RELEASE AMBIENT TEMP RATING 25.0 DEG CELSIUS NOMINAL ALL LOCATIONS
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
AAQL BODY STYLE MULTIPOLE-SINGLE ACTUATOR TYPE
AEHA DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 1.484 INCHES NOMINAL
CMLP THREAD QUANTITY PER INCH 32
ADAT BODY WIDTH 4.468 INCHES NOMINAL
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 600.0 AC ALL LOCATIONS
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED GENERAL PURPOSE

Similar Parts

KAL36150-1652 , KAL361501652 , 5925-01-234-7186 , 5925012347186 , 012347186