Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
CIRCUIT BREAKER

Definition:

A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.

CAGE Information

Code Company
74193 EATON CORP HEINEMANN PRODUCTS COMMER

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 8.0 AMPERES AC SINGLE LOCATION AND 8.0 AMPERES DC SINGLE LOCATION
BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC SINGLE LOCATION AND 200.0 DC SINGLE LOCATION
AAQL BODY STYLE SINGLE POLE TYPE
FREQ FREQUENCY IN HERTZ 50.0 SINGLE LOCATION OR 60.0 SINGLE LOCATION
AXHR MOUNTING FACILITY TYPE AND QUANTITY 1 TERMINAL
AFJN FRAGILITY FACTOR MODERATELY RUGGED
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP SINGLE LOCATION
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
CPRJ TRIP RELEASE METHOD MAGNETIC SINGLE LOCATION
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 130.0 SINGLE LOCATION
ADAV OVERALL DIAMETER 0.750 INCHES NOMINAL
ADTV CASE MATERIAL PLASTIC
AKPX POLE QUANTITY 1
CPRQ RESET METHOD MANUAL
APNQ ARC QUENCHING METHOD AIR
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 PUSH BUTTON
ADAQ BODY LENGTH 2.150 INCHES NOMINAL
TTQY TERMINAL TYPE AND QUANTITY 2 QUICK DISCONNECT, MALE
CPRW ACTUATOR FUNCTION TRIP-RESET
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 3.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 10.000 MAXIMUM AT 200 PCT SINGLE LOCATION
CBME CUBIC MEASURE 0.949 CUBIC INCHES
CPRX ACTUATOR POSITION DESIGNATION AT POLE ONE
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY SINGLE LOCATION
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 240.0 AC SINGLE LOCATION AND 32.0 DC SINGLE LOCATION

Similar Parts

KD1-8A , KD18A , 5925-01-247-9388 , 5925012479388 , 012479388