Part Number
Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
CAGE Information
Code | Company |
---|---|
02288 | ALLIED CONTROLS INC. |
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
ABMK | OVERALL WIDTH | 0.390 INCHES NOMINAL |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 34.0 MILLIAMPERES DC SINGLE WINDING |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 24.0 DC |
ABKW | OVERALL HEIGHT | 2.880 INCHES NOMINAL |
APCN | COIL QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 800.0 OHMS NOMINAL SINGLE WINDING |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 26.5 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
TTQY | TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 500.0 MILLIAMPERES AC RESISTIVE LOAD AND 500.0 MILLIAMPERES DC RESISTIVE LOAD |
APNP | DUTY TYPE | CONTINUOUS |
AYSC | PILE-UP MAIN CONTACT FORM ARRANGEMENT | 2C |
ABHP | OVERALL LENGTH | 0.800 INCHES NOMINAL |