Part Number
Part Number:
NSN:
NIIN:
Item Name:
MOTOR , ALTERNATING CURRENT
Definition:
A MOTOR WHICH IS DESIGNED FOR OPERATION FROM AN ALTERNATING CURRENT SOURCE. SEE ALSO MOTOR, CONTROL.
CAGE Information
Code | Company |
---|---|
36232 | LINCOLN ELECTRIC HOLDINGS INC. |
Federal Supply Class
Title
MOTORS, ELECTRICAL
Inclusions:
Exclusions:
EXCLUDES STARTING MOTORS FOR ENGINES.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CWGL | CURRENT RATING IN AMPS | 49.000 FIRST MULTIPLE INPUT OR 24.500 SECOND MULTIPLE INPUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
ABRR | KEYWAY WIDTH | 0.380 INCHES NOMINAL SINGLE END |
CWFY | NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 10.000 INCHES |
ANPZ | INCLOSURE FEATURE | TOTALLY INCLOSED |
AKCT | SHAFT ROTATION DIRECTION | CLOCKWISE SINGLE END OR COUNTERCLOCKWISE SINGLE END |
CBBL | FEATURES PROVIDED | HORIZONTAL MOUNTING POSITION AND VERTICAL MOUNTING POSITION |
FAAZ | PHASE | THREE INPUT |
AAJV | OVERALL WIDTH | 13.000 INCHES |
CWDM | SHAFT CENTER TO MOUNTING SURFACE DISTANCE | 6.250 INCHES SINGLE END |
ABWV | SHAFT DIAMETER | 1.620 INCHES NOMINAL SINGLE END |
CWHZ | SHAFT END CHARACTERISTIC | A9 SINGLE STYLE SINGLE END |
FREQ | FREQUENCY IN HERTZ | 60.0 INPUT |
CWDT | NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 10.000 INCHES |
TTQY | TERMINAL TYPE AND QUANTITY | 9 WIRE LEAD |
AAJT | OVERALL HEIGHT | 12.250 INCHES |
AFYS | KEYWAY LENGTH | 2.875 INCHES NOMINAL SINGLE END |
CNXS | POWER RATING | 20.000 HORSEPOWER OUTPUT |
CNMM | FRAME SIZE DESIGNATION | 256T |
BKPQ | INCLOSURE SPECIFICATION | NEMA |
AXCP | WINDING TYPE | SYNCHRONOUS |
AAJU | OVERALL LENGTH | 22.500 INCHES |
CWGQ | CONNECTION TYPE AND VOLTAGE RATING IN VOLTS | 230.0 LINE TO NEUTRAL FIRST MULTIPLE INPUT OR 460.0 LINE TO NEUTRAL SECOND MULTIPLE INPUT |
AKPS | DUTY CYCLE | CONTINUOUS |
ABRV | KEYWAY DEPTH | 0.190 INCHES NOMINAL SINGLE END |
CWFX | ROTOR SPEED RATING IN RPM | 1750.0 SINGLE FULL LOAD |
AXGY | MOUNTING METHOD | FIXED BASE |
BFMF | COOLING METHOD | FAN COOLED |
BKPB | CURRENT RATING METHOD | LOAD |
CWCS | LENGTH OF SHAFT FROM HOUSING | 4.000 INCHES SINGLE END |