Part Number
Part Number:
NSN:
NIIN:
Item Name:
REACTOR
Definition:
A COIL OR COILS USUALLY CONSTRUCTED WITH CORES HAVING LOW MAGNETIC RELUCTANCE, WHOSE PRIMARY PURPOSE IS TO FURNISH AN INDUCTIVE IMPEDANCE IN POWER OR AUDIO FREQUENCY CIRCUIT RANGING FROM ZERO TO 20 KILOHERTZ (KILOCYCLES). INCLUDES AUDIO FREQUENCY AND POWER FILTER CHOKES, AUDIO REACTORS AND SWINGING CHOKES. DOES NOT INCLUDE TRANSFORMERS OR COILS USED ABOVE AUDIO FREQUENCY RANGE. EXCLUDES SATURABLE REACTOR. FOR REACTORS WITH AIR CORES, SEE COIL (AS MODIFIED).
CAGE Information
Code | Company |
---|---|
06KW9 | LUCENT TECHNOLOGIES INC DBA FEDERAL |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
CRGS | DC RESISTANCE RATING IN OHMS | 38.500 SINGLE COMPONENT ALL WINDING |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT ALL WINDING |
ADAU | BODY HEIGHT | 3.250 INCHES NOMINAL |
AKDX | WINDING QUANTITY | 2 SINGLE COMPONENT |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.312 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACYF | INDUCTANCE TYPE | FIXED |
CRBZ | WINDING OPERATING CURRENT | 8.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE WINDING |
ADAT | BODY WIDTH | 2.625 INCHES NOMINAL |
ADAQ | BODY LENGTH | 2.125 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | OPEN |
ACYV | INDUCTANCE RATING | 750.00 MILLIHENRIES NOMINAL SINGLE COMPONENT ALL WINDING |
TTQY | TERMINAL TYPE AND QUANTITY | 4 TAB, SOLDER LUG |