Part Number
Part Number:
NSN:
NIIN:
Item Name:
TRANSFORMER , POWER AUTOTRANSFORME
Definition:
A TRANSFORMER WHICH INCORPORATES THE PRIMARY AND SECONDARY FUNCTIONS INTO A SINGLE WINDING, WHICH IS COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, AND IS DESIGNED TO CHANGE THE RELATIONSHIP OF VOLTS AND AMPERES BETWEEN THE ENTIRE WINDING AND ITS TAPS. INCLUDES MULTIPLE WINDING TRANSFORMERS OF LIKE DESIGN AND ITEMS IN WHICH A VARIATION OF THE TURNS RATIO OR INDUCTIVE RATIO OF INDUCTIVE COUPLING IS ACCOMPLISHED BY CONNECTION TO FIXED TERMINALS. ALSO, INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO IN PROGRESSIVE INCREMENTS, BY MEANS OF A SHAFT, VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OF SIMILAR DESIGN. EXCLUDES TRANSFORMER (1), POWER; TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
64959 | AMERICAN TELEPHONE AND TELEGRAPH CO |
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
CRMJ | WINDING POWER RATING | 62.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY INPUT |
CQLC | WINDING TAP LOCATION (NON-CORE) | MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE SECONDARY |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CWJS | WINDING OPERATING VOLTAGE | 89.45 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY OUTPUT OR 93.36 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY OUTPUT OR 96.88 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY OUTPUT OR 72.24 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY OUTPUT OR 82.02 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY OUTPUT OR 78.11 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY OUTPUT OR 100.40 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY OUTPUT OR 69.50 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY OUTPUT OR 104.31 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY OUTPUT OR 85.93 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY OUTPUT OR 75.73 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY OUTPUT OR 107.83 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
ADAT | BODY WIDTH | 3.000 INCHES NOMINAL |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY INPUT |
AARD | DUMMY TERMINAL QUANTITY (NON-CORE) | 1 |
ADAU | BODY HEIGHT | 2.625 INCHES NOMINAL |
ADAQ | BODY LENGTH | 3.250 INCHES NOMINAL |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT |
TTQY | TERMINAL TYPE AND QUANTITY | 13 WIRE LEAD |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AKNA | INCLOSURE TYPE | OPEN |
ACZB | FREQUENCY RATING | 400.0 HERTZ MINIMUM SINGLE COMPONENT AND 2.4 KILOHERTZ MAXIMUM SINGLE COMPONENT |