Part Number
Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
CAGE Information
Code | Company |
---|---|
36090 | LOCKHEED MARTIN LIBRASCOPE CORP |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC LAMP LOAD AND 2.0 AMPERES DC LAMP LOAD |
AKDX | WINDING QUANTITY | 1 |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
ABMK | OVERALL WIDTH | 1.025 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
ZZZK | SPECIFICATION/STANDARD DATA | 96906-MS27400 GOVERNMENT STANDARD AND 81349-MIL-PRF-83536A GOVERNMENT STANDARD |
CSQJ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 1.396 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 1.446 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 1.010 INCHES MAXIMUM |
FEAT | SPECIAL FEATURES | FAILURE RATE 3.0 PERCENT PER 10,000 CYCLES; TEMP RANGE MINUS 70.0 DEG TO PLUS 125.0 DEG C; SOCKET PIN TERMINAL RELAY HAS SILICONE GASKET 0.050 INCH NOMINAL THICKNESS POSITIONED AGAINST BOTTOM OF CASE AT THE BASE OF 0.270 INCH NOMINAL LENGTH PINS; SOCKET PIN TERMINAL RELAYS HAVE 0.062 INCH DIA PINS |
APCN | COIL QUANTITY | 1 |
CQYJ | MOUNTING FACILITY PATTERN | TRIANGLE SINGLE MOUNTING FACILITY |
PMLC | PRECIOUS MATERIAL AND LOCATION | SOCKET PIN TERMINALS GOLD |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.625 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AJSS | FREQUENCY IN HERTZ | 400.0 MAXIMUM |
APNQ | ARC QUENCHING METHOD | AIR |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-6106 SPECIFICATION AND 81349-MIL-PRF-83536 STANDARD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 8.0 AMPERES AC INDUCTIVE LOAD AND 8.0 AMPERES DC INDUCTIVE LOAD |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 4.0 AMPERES AC MOTOR LOAD AND 4.0 AMPERES DC MOTOR LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC |
APNP | DUTY TYPE | CONTINUOUS |
TTQY | TERMINAL TYPE AND QUANTITY | 14 PIN ALL FUNCTIONS |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD AND 10.0 AMPERES DC RESISTIVE LOAD |
ABTD | MOUNTING SLOT WIDTH | 0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABHP | OVERALL LENGTH | 1.718 INCHES NOMINAL |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 4 POLE, DOUBLE THROW, TWO POSITIONS MOMENTARY |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 3 SLOTTED HOLE SINGLE MOUNTING FACILITY |