TRANSFORMER , POWER
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
CAGE Information
Code |
Company |
36090 |
LOCKHEED MARTIN LIBRASCOPE CORP |
Characteristics (Decoded)
MRC |
Requirements Statement |
Clear Text Reply |
AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
ABKW |
OVERALL HEIGHT |
1.380 INCHES MAXIMUM |
ABHP |
OVERALL LENGTH |
3.680 INCHES MAXIMUM |
TTQY |
TERMINAL TYPE AND QUANTITY |
9 EYELET |
ABTB |
MOUNTING HOLE DIAMETER |
0.150 INCHES NOMINAL SINGLE GROUP |
FEAT |
SPECIAL FEATURES |
VOLT AMPERE RATING 42 VA MIN |
CWJS |
WINDING OPERATING VOLTAGE |
81.60 AC POUNDS PER HOUR DRY SINGLE COMPONENT 1ST SECONDARY AND 88.40 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 1ST SECONDARY |
CWJS |
WINDING OPERATING VOLTAGE |
223.68 AC POUNDS PER HOUR DRY SINGLE COMPONENT 2ND SECONDARY AND 242.32 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 2ND SECONDARY |
ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
ABMK |
OVERALL WIDTH |
2.700 INCHES MAXIMUM |
ADAU |
BODY HEIGHT |
1.380 INCHES MAXIMUM |
CWJS |
WINDING OPERATING VOLTAGE |
103.50 AC POUNDS PER HOUR DRY SINGLE COMPONENT SINGLE PRIMARY AND 126.50 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT SINGLE PRIMARY |
BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
2.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AXGY |
MOUNTING METHOD |
UNTHREADED HOLE SINGLE GROUP |
ACZX |
WINDING SHIELDING METHOD |
INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
ACZD |
TRANSFORMER WINDING CONNECTION TYPE |
DELTA-DELTA |
ADAQ |
BODY LENGTH |
3.680 INCHES MAXIMUM |
ACZB |
FREQUENCY RATING |
380.0 HERTZ MINIMUM SINGLE COMPONENT AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT |
AKNA |
INCLOSURE TYPE |
OPEN |
ADAT |
BODY WIDTH |
1.620 INCHES MAXIMUM |