Part Number
Part Number:
NSN:
NIIN:
Item Name:
AMPLIFIER , RADIO FREQUENCY
Definition:
AN ELECTRONIC DEVICE WHOSE RADIO FREQUENCY INPUT SIGNALS CONTROL POWER FROM A SOURCE INDEPENDENT OF THE INPUT SIGNALS, AND DELIVERS RADIO FREQUENCY OUTPUT SIGNALS OF GREATER AMPLITUDE WITH RESPECT TO CURRENT AND/OR VOLTAGE. THE OUTPUT SIGNALS CHARACTERISTICS ARE UNIFORMLY RELATED TO THE INPUT SIGNALS. IT OPERATES AT FREQUENCIES ABOVE 20 KILOHERTZ.
CAGE Information
Code | Company |
---|---|
34874 | M P D TECHNOLOGIES INC |
Federal Supply Class
Title
AMPLIFIERS
Inclusions:
INCLUDES AUDIO AMPLIFIERS, COMPLEMENTARY AMPLIFIERS, AMPLIFIERS, OPERATIONAL AMPLIFIERS, POWER AMPLIFIERS, RADIO FREQUENCY AMPLIFIERS, SIGNAL AMPLIFIERS, VIDEO AMPLIFIERS, AND MAGNETIC AMPLIFIERS.
Exclusions:
EXCLUDES MULTI-FUNCTIONAL ITEMS SUCH AS AMPLIFIER-DETECTOR, AMPLIFIER-MIXER AND MICROCIRCUIT DEVICES.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABKW | OVERALL HEIGHT | 3.500 INCHES NOMINAL |
BHTL | OVERALL GAIN | 40.0 DECIBELS |
AQZF | CONTROL TYPE | LOCAL |
BHTJ | AVERAGE POWER RATING PER CHANNEL | 10.0 WATTS OUTPUT |
FEAT | SPECIAL FEATURES | IEEE-488 CONTROL; 0.5 TO 1.0GHZ RANGE; CW/PULSE OPERATING MODE; 25MICROSEC TO CW PULSE WIDTH; 50NANOSEC RISE/FALL TIME; 1.5:1 VSWR IN 2.5:1 OUT |
AGTA | BASIC SHAPE STYLE | RECTANGULAR OR SQUARE |
FCLS | FUNCTIONAL CLASSIFICATION | AA-11.5 |
ABHP | OVERALL LENGTH | 24.700 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 19.000 INCHES NOMINAL |
RTSE | RELATIONSHIP TO SIMILAR EQUIPMENT | PART NO LAB4-055-10/7477 50-500MHZ; LAB4-1020-10/7477 1.0-2.0GHZ |
BHTN | IMPEDANCE RATING PER CHANNEL | 50.000 OHMS OUTPUT CHANNEL |
FTLD | FUNCTIONAL DESCRIPTION | CLASS A AMPLIFIER PROVIDES 10WATTS OUTPUT OVER 50 TO 1000MHZ; INCLUDES PROVISIONS FOR INTERNAL/EXTERNAL LEVELLING & MODULATION AND OUTPUT POWER CONTROL |
AFSU | AVERAGE LIFE MEASUREMENT | INDEFINITE |
AMQY | INSTALLATION DESIGN | RACK AND TOP OF CABINET/COUNTER |
BHSX | CIRCUIT CONSTRUCTION TYPE | SOLID STATE |
AKNA | INCLOSURE TYPE | ENCASED |
ALBM | OPERATING CONTROL METHOD | AUTOMATIC OR MANUAL |