Part Number
Part Number:
NSN:
NIIN:
Item Name:
WAVEGUIDE ASSEMBLY
Definition:
AN ITEM CONSISTING OF ONE OR MORE DEFINITE LENGTHS OF STRAIGHT OR FORMED, FLEXIBLE OR RIGID, PREFABRICATED HOLLOW TUBING OF CONDUCTIVE MATERIAL. THE TUBING HAS A PREDETERMINED CROSS SECTION AND IS DESIGNED TO GUIDE OR CONDUCT HIGH FREQUENCY ELECTROMAGNETIC ENERGY THROUGH ITS INTERIOR. ONE OR MORE ENDS ARE TERMINATED. MAY INCLUDE COMMON MOUNTING OF A SWITCH, WAVE GUIDE, A DUMMY LOAD, ELECTRICAL AND OTHER COMPONENTS SUCH AS WAVEGUIDE SECTION, CABLE TERMINAL CHAMBER AND THE LIKE. EXCLUDES COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; AND TUNER, WAVEGUIDE.
CAGE Information
Code | Company |
---|---|
43999 | BOEING COMPANY THE DBA BOEING DIV DE |
Federal Supply Class
Title
ANTENNAS, WAVEGUIDES, AND RELATE
Inclusions:
INCLUDES AERIALS; MASTS; TOWER EQUIPMENT; ATTENUATORS; COUPLERS; TRANSMISSION LINES.
Exclusions:
EXCLUDES TOWER STRUCTURES.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AHTW | VOLTAGE STANDING WAVE RATIO | 1.40 |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.144 INCHES MINIMUM FIRST FLANGE ALL CONNECTION FACILITIES AND 0.147 INCHES MAXIMUM FIRST FLANGE ALL CONNECTION FACILITIES |
AHSX | FLANGE INSIDE WIDTH | 0.854 INCHES MINIMUM FIRST FLANGE AND 0.856 INCHES MAXIMUM FIRST FLANGE |
AHSF | FLANGE QUANTITY | 2 |
CQGM | MAXIMUM OPERATING PRESSURE | 45.0 POUNDS PER SQUARE INCH GAGE |
AHSY | FLANGE INSIDE HEIGHT | 0.479 INCHES MINIMUM FIRST FLANGE AND 0.481 INCHES MAXIMUM FIRST FLANGE |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.372 INCHES MINIMUM AND 0.378 INCHES MAXIMUM |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 0.847 INCHES MINIMUM AND 0.853 INCHES MAXIMUM |
AHSZ | FLANGE OUTSIDE WIDTH | 1.485 INCHES MINIMUM FIRST FLANGE AND 1.515 INCHES MAXIMUM FIRST FLANGE |
CRFH | WAVEGUIDE INSIDE WIDTH | 0.747 INCHES MINIMUM AND 0.753 INCHES MAXIMUM |
MATT | MATERIAL | ALUMINUM ALLOY ALL TUBING SEGMENT AND FLANGE |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |
FLEX | FLEXIBILITY | RIGID SINGLE TUBING SEGMENT |
AHTD | FLANGE DEPTH | 0.376 INCHES MINIMUM FIRST FLANGE AND 0.406 INCHES MAXIMUM FIRST FLANGE |
CTCJ | FLANGE STYLE | COVER TYPE FIRST FLANGE |
AHTX | INSERTION LOSS IN DECIBELS | 0.65 |
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.472 INCHES MINIMUM AND 0.478 INCHES MAXIMUM |
AHTA | FLANGE OUTSIDE HEIGHT | 1.415 INCHES MINIMUM FIRST FLANGE AND 1.515 INCHES MAXIMUM FIRST FLANGE |