Part Number
Part Number:
NSN:
NIIN:
Item Name:
REACTOR
Definition:
A COIL OR COILS USUALLY CONSTRUCTED WITH CORES HAVING LOW MAGNETIC RELUCTANCE, WHOSE PRIMARY PURPOSE IS TO FURNISH AN INDUCTIVE IMPEDANCE IN POWER OR AUDIO FREQUENCY CIRCUIT RANGING FROM ZERO TO 20 KILOHERTZ (KILOCYCLES). INCLUDES AUDIO FREQUENCY AND POWER FILTER CHOKES, AUDIO REACTORS AND SWINGING CHOKES. DOES NOT INCLUDE TRANSFORMERS OR COILS USED ABOVE AUDIO FREQUENCY RANGE. EXCLUDES SATURABLE REACTOR. FOR REACTORS WITH AIR CORES, SEE COIL (AS MODIFIED).
CAGE Information
Code | Company |
---|---|
15634 | MAGNETIKA INC |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
CQJX | NOMINAL THREAD SIZE | 0.086 INCHES SINGLE GROUP |
ADAT | BODY WIDTH | 4.000 INCHES NOMINAL |
AKDX | WINDING QUANTITY | 1 SINGLE COMPONENT |
TTQY | TERMINAL TYPE AND QUANTITY | 2 THREADED STUD |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
ADAU | BODY HEIGHT | 4.688 INCHES NOMINAL |
CMLP | THREAD QUANTITY PER INCH | 20 SINGLE GROUP |
AAJF | THREAD DIRECTION (NON-CORE) | RIGHT-HAND SINGLE GROUP |
ADAQ | BODY LENGTH | 6.000 INCHES NOMINAL |
ACYV | INDUCTANCE RATING | 1.20 MILLIHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING |
ACZB | FREQUENCY RATING | 180.0 HERTZ NOMINAL SINGLE COMPONENT |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 7.250 INCHES NOMINAL |
CRGS | DC RESISTANCE RATING IN OHMS | 0.050 SINGLE COMPONENT SINGLE WINDING |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.638 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
ACYF | INDUCTANCE TYPE | FIXED |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT SINGLE WINDING |
AAJD | THREAD CLASS (NON-CORE) | 2A SINGLE GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CRBZ | WINDING OPERATING CURRENT | 50.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE WINDING |