TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

CAGE Information

Code Company
90095 PULSE ELECTRONICS DBA PULSE COMPONEN

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
ADAU BODY HEIGHT 2.600 INCHES MAXIMUM
AAJD THREAD CLASS (NON-CORE) 2B SINGLE GROUP
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT
THSD THREAD SERIES DESIGNATOR UNC SINGLE GROUP
CRMJ WINDING POWER RATING 500.0 MILLIWATTS SINGLE COMPONENT 3RD SECONDARY
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.290 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.310 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ADAQ BODY LENGTH 2.518 INCHES MINIMUM AND 2.738 INCHES MAXIMUM
AAJF THREAD DIRECTION (NON-CORE) RIGHT-HAND SINGLE GROUP
ACZB FREQUENCY RATING 10.0 KILOHERTZ NOMINAL SINGLE COMPONENT
AARG RELIABILITY INDICATOR NOT ESTABLISHED
AXGY MOUNTING METHOD THREADED HOLE SINGLE GROUP
CQLC WINDING TAP LOCATION (NON-CORE) MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT 3RD SECONDARY
CWJS WINDING OPERATING VOLTAGE 100.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
CQJX NOMINAL THREAD SIZE 0.138 INCHES SINGLE GROUP
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.790 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.810 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
AKNA INCLOSURE TYPE HERMETICALLY SEALED
ADAT BODY WIDTH 1.800 INCHES MAXIMUM
CWJS WINDING OPERATING VOLTAGE 3.30 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY AND 6.16 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY AND 4.237 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY AND 7.76 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY
CWJS WINDING OPERATING VOLTAGE 12.20 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY
TTQY TERMINAL TYPE AND QUANTITY 14 TURRET
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
CQLC WINDING TAP LOCATION (NON-CORE) MULTIPLE TAPS W/CENTER TAP SINGLE COMPONENT SINGLE PRIMARY
CWJS WINDING OPERATING VOLTAGE 5.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 26.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 31.10 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
CRMJ WINDING POWER RATING 30.0 WATTS SINGLE COMPONENT 1ST SECONDARY
CRBZ WINDING OPERATING CURRENT 15.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE PRIMARY