TWO OR MORE INDIVIDUALLY INSULATED CONDUCTORS (SOLID OR STRANDED) CONTAINED IN A COMMON COVERING, OR TWO OR MORE INDIVIDUALLY INSULATED CONDUCTORS TWISTED OR MOLDED TOGETHER WITHOUT A COMMON COVERING, OR ONE INSULATED CONDUCTOR WITH A METALLIC COVERING OR SHIELD; EACH HAVING CHARACTERISTICS NOT COMPLETELY CONFORMING TO CABLE, TELEPHONE; CABLE, POWER, ELECTRICAL; CABLE, RADIO FREQUENCY OR CORD, ELECTRICAL. INCLUDES ITEMS HAVING THE COMBINED CHARACTERISTICS OF TWO OR MORE OF THE AFOREMENTIONED NAMES. REFERS TO BULK QUANTITIES ONLY; FOR ITEMS OF DEFINITE LENGTH WITH PROCESSED ENDS OR TERMINATED IN FITTINGS, SEE CABLE ASSEMBLY, SPECIAL PURPOSE, ELECTRICAL.
CAGE Information
Code | Company |
---|---|
16236 | DLA LAND AND MARITIME |
Federal Supply Class
Title
WIRE AND CABLE, ELECTRICAL
Inclusions:
INCLUDES INSULATED AND NONINSULATED, WIRE AND CABLE, SUCH AS, ANTENNA WIRE, COAXIAL CABLE, FUSE AND RESISTANCE WIRE, AND MAGNET WIRE.
Exclusions:
EXCLUDES RADIO FREQUENCY TRANSMISSION LINE (FSC 5985); FIBER OPTIC CABLE (FSC 6015); COMMUNICATION CABLE ASSEMBLIES (FSC 5995); DISTRIBUTION AND POWER TRANSMISSION CABLE ASSEMBLIES (FSC 6150).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
FEAT | SPECIAL FEATURES | PAINT ALUMINUM TT-P-320 ON ARMOR AND POLYESTER TAPE UNDER OUTER JACKET IS OPTIONAL. REFERENCE NUMBER DIFFERENTIATING MATERIAL WILL BE IN ACCORDANCE WITH NAVAL INVENTORY CONTROL POINT ACTIVIY HS QUALITY CONTROL. MANUFACTURING AND TESTING SPECIFICATIONS AVAILABLE AT THE DLA ICP; ITEM MUST COMPLY WITH REQUIREMENTS OF DEFENSE SUPPLY CENTER COLUMBUS PRODUCTION STANDARD NO. LO5130. |
AAGR | CROSS-SECTIONAL SHAPE STYLE | ROUND |
AMQN | CONDUCTOR QUANTITY | 20 |
CXDC | ROUND CONDUCTOR SIZE | 22 AWG ALL CONDUCTORS |
CXFK | VOLTAGE RATING | 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS |
BLNZ | STRAND QUANTITY PER CONDUCTOR | 7 ALL CONDUCTORS |
CXDQ | CONDUCTOR ARRANGEMENT AND QUANTITY | 10 TWISTED PAIR |
CXDG | STRAND AWG SIZE PER CONDUCTOR | 30 ALL CONDUCTORS |
ADVL | CROSS SECTION OUTSIDE DIAMETER | 0.516 INCHES NOMINAL |
CXCW | CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | ASTMB3 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS |